Fault rectifi cation
DEFECT
The appliance
does not work.
The appliance
stops suddenly.
The motor runs, but
the accessory parts
do not rotate.
SKM 500 A1
CAUSE
The plug is not
connected.
The appliance is not
correctly assembled
and engaged.
The appliance is
defective.
The lid 3 of the
appliance may have
become loose when
processing hard
ingredients.
The appliance is
defective.
The drive shaft i is
not inserted properly.
SOLUTION
Insert the plug into a mains
power socket.
Check the assembly of the
appliance and ensure that all
marks are correctly aligned.
In this case, contact the
Customer Services.
Replace the lid 3.
In this case, contact the
Customer Services.
Check the assembly of the
drive shaft i.