Technical Characteristics - Ugolini A12 Carnet D'instructions

Masquer les pouces Voir aussi pour A12:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1 TECHNICAL CHARACTERISTICS

Transparent
removable
bowls
Capacity
of
each
approx.
Dimensions:
width
depth
height
Net weight, approx.
Gross weight, approx.
Adjustable thermostats
Hermetic compressor
Air-cooled condenser
Overload protector
Noise level lower than 70 dB (A)
IMPORTANT
Read electrical ratings written on the data
plate under the individual units. The serial
number of the unit is preceded by the
symbol #. Data plate specifications will
always supersede the information in this
manual.
Specifications are subject to change without
notice.
2 INTRODUCTION
Please read all sections of this manual thoroughly
to familiarize yourself with all aspects of the unit.
Like all mechanical products, this machine will
require cleaning and maintenance. Besides,
dispenser working can be compromised by
operator's mistakes during disassembly and
cleaning. It is strongly recommended that
personnel responsible for the equipment's daily
operations, disassembly, cleaning, sanitizing and
assembly, go through these procedures in order
to be properly trained and to make sure that no
misunderstandings exist.
A 12 A 19
n
1
1
bowl,
l
12
19
cm 32
32
cm 40
40
cm 64
70
kg 20
20
kg 23
23
n
1
1
3 INSTALLATION
1
Remove the corrugate container and packing
materials and keep them for possible future use.
2
Inspect the uncrated unit for any possible
damage. If damage is found, call the delivering
carrier immediately to file a claim.
3
Install the unit on a counter top that will
support the combined weight of dispenser and
product.
4
A minimum of 15 cm (6") of free air space all
around the unit should be allowed to guarantee
adequate ventilation.
5
Ensure that the legs are screwed tightly into
the base of the machine.
6
Before plugging the unit in, check if the
voltage is the same as that indicated on the data
plate. Plug the unit into a grounded, protected
single phase electrical supply according to the
applicable electrical codes and the specifications
of your machine. When the unit has no plug,
install a proper grounded plug, in compliance
with electrical codes in force in your area,
suitable to at least 10 Amp 250 Volt (220-
230 Volts 50-60 Hz areas) and 20 Amp 250 Volt
(100-115 Volts 50-60 Hz areas) applications.
Should you prefer to connect the unit directly to
the mains, connect the supply cord to a 2-pole
wall breaker, whose contact opening is at least 3
mm. Do not use extension cords.
ATTENTION
Failure to provide proper electrical ground
according to applicable electrical codes
could result in serious shock hazard.
7
The unit doesn't come presanitized from the
factory. Before serving products, the dispenser
must be disassembled, cleaned and sanitized
according to this handbook instructions (chapter
5 . 3 C L E A N I N G A N D S A N I T A Z I N G
PROCEDURES).
IMPORTANT
Install the dispenser so that the plug is
easily accessible.
4 TO OPERATE SAFELY
1
Do not operate the dispenser without
reading this operator's manual.
2
Do not operate the dispenser unless it is
properly grounded.
9