Carry out the connection of the device  to the controller / other mod-
ules in the order described below:
The KM2 Communication module comes with the VBus
further VBus
®
cable is to be connected, proceed as follows:
Î In order to open the housing, unscrew the screw and remove the upper part
of the housing.
Î Connect the 2-wire cable (bell wire) to the 2 VBus
any polarity, see chap. 3.3 on page 22.
Î Close the housing.
Î Connect the data cable (RESOL VBus
essary, extend the cable using the terminal block included and a 2-wire cable
(bell wire).
Î Connect VBus
®
accessory  via the data cable, if necessary.
Î Connect the device to the mains by means of the mains adapter .
Î For a direct connection to a router, connect the device to a router  using the
network cable (included with the device, ).
Power supply is carried out via an external mains adapter. The supply voltage of the
mains adapter must be 100 ... 240 V~ (50 ... 60 Hz).
22
cable pre-connected. If a
®
terminals (C) and (D) with
®
®
, ) to a RESOL controller . If nec-
www
3.3
VBus
/ Data communication
®
The KM2 Communication module is connected to the controller via the pre-con-
nected VBus
®
cable. The corresponding terminal allocation is described in the con-
troller manual.
The VBus
cable can be extended using the terminal block included and a 2-wire
®
cable.
With the RESOL VBus
and the communication module are possible.
Connection terminals of the Communication module
TheVBus
®
cable is pre-connected to the KM2 terminals (A) and (B). A further
module such as a SD3, extension module or alarm module can be connected to
the terminals (C) and (D).
3.4

LAN connection

The KM2 Communication module can be connected to a router by using a net-
work cable (CAT5e, RJ45 or similar).
Î Connect the network cable included to the LAN connector of the router and
to the LAN connector of the KM2.
For the next step of commissioning, see chap. 5 on page 23.
The LAN connector is located on the front side of the device and supports trans-
fer rates of up to 100 MBit per second.
-Repeater distances of up to 150 m between the controller
®
(A) (B) (C) (D)