Up to firmware V2.0.8 / V2.1.2 build 200410:
The security module still has to be configured as a new door relay. To do this, open the remote
configuration of the door video module with the ABUS CMS software and go to the "Intercom" /
"IO In Out" menu and set "IO Out" for "DOOR 1" to "securityModule"
From firmware V2.2.3 / V2.1.2 build 201029:
After connecting the safety module, it is automatically recognized.
Now the relay security module will be triggered instead of the internal relay for the door video
intercom module when the door is opened. While the relay is active, the green LED "Relay" will
light up on TVHS10040.
Attention:
Only one security module TVHS10040 / TVHS20340 may be used per video door
module!
Note:
The security module is always the last module connected, whether there is only a video
door module or additional extension modules are connected.
max. 2A 30VDC / 0.5A 125AC
Maximum relay load:
127