BIO UV MP030 Serie Notice De Montage Et D'entretien page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
MP 030 EL NM GB
Marque, Modèles et Brevets déposés - Produits exclusifs
USE AND MAINTENANCE
● Allow the ultraviolet lamp to cool for at least 30 minutes before handling.
● Never look at the ultraviolet lamps when lit. This may cause severe injuries
or burns and may even lead to loss of eyesight.
● Do not touch the ultraviolet lamp with bare hands, as these would leave
impurities that shorten the life of the lamp. If you do touch it: clean with alcohol
or white vinegar.
● Never unscrew the quartz tube sealing nut when the reactor is on load as the
quartz tube could be blown out of the reactor with force and injure you.
● Do not use the reactor if the power supply wire is worn or damaged. In this
case it should be replaced.
● If the connecting cable between the reactor and the electrical cabinet is
damaged, it must be replaced by a special cable available as a spare part.
● Even when stopped, power is present in the electrical unit so make sure
that the main power supply upstream of the electrical cabinet is switched off
before carrying out any work on the equipment.
● To avoid electric short-circuits, do not place the electric wires or the reactor in
the pool water or in any other maintenance or cleaning fluid.
● Do not restart the system until the electric unit, the covers exterior elements of
the reactor are correctly back in place.
● Do not use the BIO-UV reactor for any other use than that for which it was
designed.
Copyright BIO-UV - 29/01/2009
Page 8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mp030 elMp030 nmMp030 es

Table des Matières