CONTENT OF MENUS AND SUB-MENUS:
Use the + or – keys to change from one menu to another.
Press on key A for 5 seconds to enter a menu.
When the word "OFF" is displayed, this means that the display option is not available on your device.
A
A1
A2
A3
B
B1
C
D
E
E1
F
G
G1
MP 030 EL NM GB
Marque, Modèles et Brevets déposés - Produits exclusifs
Display of UVC intensity measured by the sensor.
N.B.: each time the lamp is changed, you MUST calibrate the sensor even if the display
already shows 100%.
Calibrating the sensor:
● It is important to carry out this operation when commissioning the reactor and also when
changing a lamp even if the display already shows 100%.
● It is important to wait 5 minutes before carrying out the calibration, to allow the lamps
to heat up.
● If your device is equipped with the power regulator, it is ESSENTIAL to switch over to
manual regulation (100%) before calibrating the sensor..
Menu for adjusting the pre-alarm threshold. Set in the factory at 75%.
Allows you to set the UVC value at which the pre-alarm will trigger.
Menu for adjusting the main alarm threshold. Set in the factory at 50%.
Allows you to set the UVC value at which the main alarm will trigger.
Display of lamp operating time. It is recommended to reset this counter at zero when you
change a lamp.
Reset the hour counter and the number of lamp start-ups at zero.
Display the reactor's total operating time since commissioning. This counter cannot be reset at
zero..
Display of the number of lamp start-ups carried out. Resetting at zero is linked to that of the
hour counter.
Display of the total number of cleaning operations carried out since the reactor was
commissioned. This counter cannot be reset at zero.
Adjustment of the frequency of the automatic cleaning cycle. Factory setting: one cleaning
cycle every 6 hours. Can be increased to a maximum of one cleaning cycle per hour.
Display of the reactor temperature.
Display of the type of power regulation used.
Power regulation:
Allows you to set the type of power regulation of the UV lamps.
● On automatic regulation, the power switches automatically from 75% to 100% and back
depending on the reactor operating conditions.
● On automatic regulation, the lamps are always at 100% power.