PROCEDURE CHANGEMENT LAMPES ET GAINES QUARTZ
1
2
3
4
5
6
7
8
9
MP 030 NM FR
MARQUE, MODELES ET BREVETS DEPOSES - PRODUITS EXCLUSIFS
LE STERILISATEUR DOIT ETRE
HORS TENSION, ISOLÉ ET VIDANGÉ.
DEVISSER ET RETIRER LES 2 CAPOTS DU
DECABLER LA LAMPE DES DEUX COTES DU
(SEULEMENT LES CABLES BLANCS
ALIMENTANT LA LAMPE).
DE CHAQUE COTE, DEMONTER LES SUPPORTS
LAMPE EN DEVISSANT LES 3 VIS.
ASSUREZ-VOUS QUE LA LAMPE SOIT
SUFFISAMMENT REFROIDIE AVANT DE LA
RETIRER LA LAMPE ACCOMPAGNEE DE SES
SUPPORTS TEFLON (S'IL Y EN A) ET DEPOSEZ-
LA SUR UNE SURFACE PROPRE ET DOUCE.
EFFECTUER CETTE OPERATION DELICATEMENT
SANS TOUCHER LE VERRE DE LA LAMPE AVEC
DEVISSER LES ECROUS INOX DES DEUX COTES
ET ENLEVER LES RONDELLES ALUMINIUM.
RETIRER SOIGNEUSEMENT LA GAINE
● POUSSER LA GAINE QUARTZ POUR
POUVOIR L'ATTRAPER DE L'AUTRE COTE.
● RETIRER ENTIEREMENT LA GAINE
QUARTZ ET SES JOINTS D'ETANCHEITE.
NETTOYER LA GAINE QUARTZ AVEC DE
L'ACIDE OU DU VINAIGRE BLANC OU LA
CHANGER SI NECESSAIRE.
IMPERATIVEMENT
REACTEUR.
REACTEUR
MANIPULER.
LES MAINS.
QUARTZ :
COPYRIGHT BIO-UV - 04/02/2009
PAGE 23