RECOMMENDED INSPECTIONS AND PREVENTIVE MAINTENANCE
0
Changing UV lamps
OPERATIONS
Checking the general state of the UV
reactor
1
Replacement of quad ring seals
2
Checking the presence of quartz sheath
Teflon shims
3
Cleaning or replacing the quartz sheath
4
Replacing the cleaning wipers
5
Cleaning the UV sensor
6
Check the operation of the flowmeter
7
Check the operation of ventilators:
- Cleaning grills
- Filter replacement (if applicable)
8
UV sensor calibration
9
Pneumatic silencer replacement
10
Check the earthing of the reactor
11
Check the operation of the thermostat in the
electrical cabinet
12
Check the operation of the circuit breaker
13
Check tightening:
- Of terminal blocks in the cabinet
- Of connectors
- Of UV lamp connections
MP 030 EL NM GB
Marque, Modèles et Brevets déposés - Produits exclusifs
At the end of their life span:
- either display on the Millénium III monitor: UV
intensity <50%
- or combined chlorine rate in the basin
ON EACH UV LAMP

CHANGEOVER

Compulsory
Compulsory
Compulsory
Compulsory
Compulsory
Recommended
Only new lamps, quartz sheath clean or new, UV
sensor cleaned
Only in the event of corrosion
Recommended
Recommended
Recommended
AT LEAST ONCE
PER YEAR
Compulsory
Recommended
Compulsory
Compulsory
Copyright BIO-UV - 29/01/2009
Page 19