CHANGING UV LAMP AND QUARTZ SLEEVE
1
2
3
4
5
6
7
8
9
10
MP 030 EL NM GB
Marque, Modèles et Brevets déposés - Produits exclusifs
SWITCH OFF the reactor, CUT the POWER source and EMPTY IT
Unscrew and remove the 2 covers.
Remove the wires from the lamp on both sides by unscrewing the terminals (only
the cables white supplying the lamp).
Unscrew the aluminium lamp base, 3 screws, on both sides.
Make sure that the UV lamp is cooled before handle it.
Take out the lamp together with its Teflon supports (if there are any) and place it
on a clean and soft surface.
Carry out this operation CAREFULLY taking care not to place your fingers
outside the cap.
Unscrew the MP nuts on both sides and remove the aluminium washer.
Gently remove the quartz sleeve:
● Push one end of the quartz sleeve in order to pull the other end.
● Remove the quartz sleeve and its seals.
Clean the quartz sleeve with acid or white vinegar or replace it if necessary.
While remaining in the axis, gently reposition the quartz sleeve in the direction
indicated by the label on the reactor.