Control Panel - LORCH ControlPro MicorStick 200 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 114

13 Control panel

11
20
19
Fig. 7:
Bedienfeld MicorStick 200 ControlPro
LED malfunction
11
lights up permanently if the unit is overheated,
flashing in case of malfunction (see chapter for
trouble reports), ignition of arc is not possible.
LED remote control
12
lights up when remote control is connected.
The turning knob 13 displays the maximum value
for the setting range of the control. I.e. if 100A are
set, the remote can recall 10A-100A.
Turning knob
13
for welding current adjustment for the stepless
setting of welding current.
Both to select the parameter and to set the pa-
rameter values.
LED TIG
14
lights up if TIG mode is selected.
LED Elecrode basic
15
lights up if electrode mode is selected.
(electrodes with basic coating)
LED Elecrode rutile
16
lights up if rutile electrode mode is selected.
(electrodes with rutile acidic coating)
- 26 -
12
13
LED Electrode CEL
17
lights up if CEL electrode mode is selected.
(electrodes with cellulose coating, suitable for
vertical seams)
Key switch electrode/TIG
18
serves to select the operating mode.
To set TIG mode, keep the key presses for at
least 2 seconds.
Menu/Secondary parameter button
19
used for calling up the secondary parameters.
The 7 segment display, shows the selected cur-
20
rent intensity.
When the secondary parameters are active,
the code and the setting value of the secondary
parameter are displayed alternately.
‰ After switching on the unit
– all displays will flash for approx. 2 seconds for self-
testing.
– the last setting will be selected
909.2779.9-00
Control panel
14
15
16
17
18
09.16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Controlpro micorstick 200 rc

Table des Matières