NOTICE: A ventilation cross-section of 200cm² as required for heating rooms is sufficing.
Ventilate the store room before and during entering and the fresh air supply has to be guaranteed. More information see ÖNORM M 7137:2012.
THESE ROOMS MUST BE RETROFITTED WITH A PERMANENT VENTILATION TO THE OUTSIDE!
Damp rooms, for example in the basement should not be a problem, but the sack silo may not lean against damp walls. UV-lightening must be
avoided (e.g.: affix UV-foil onto the windows). Sharp items must be encased or removed.
Basically, the room size has to be chosen in a way, so that an easy assembly of the pelletbox is possible.
The sides of the installation room must at least be 50mm wider than the pelletbox. On the wall opposite to the
filling nozzles the minimum distance to the pelletbox must be minimum 100mm.
For information on the distance of the wall to the filling nozzles check the sketches under point 5 mounting
versions/filling the pelletbox. Up to the ceiling the maximum room height can be utilized.
Basically, it is also possible to set up the pelletbox outside. The pelletbox must be protected from weather effects
(rain, wind and UV light). A watertight roof and side cladding are absolutely necessary. Also the hoses have
to be protected from UV light.

3.2. FIRE SAFETY

FOR FIRE REGULATION ASK THE RESPECTIVE FIRE PREVENTION AUTHORITY!
Austria:
TRVB H 118 „automatic wood firing facilities", BVS data sheet Nr. 029 „wood-pellets heater"
German:
See heater regulation.
France:
Still no detailed guidelines available, please contact you the responsible fire-brigade management.
Switzerland:
See to fire protection regulations for pellet firing www.vkf.ch.
Italy:
Regulation of the ministry of the Interior 28 April 2005: Technical fire protection regulation for planning and the structure of heating systems
with liquid and solid fuels. More exact details please contact you the responsible fire-brigade management.
MOUNTING IN UNVENTILATED ROOMS IS PROHIBITED!

