Assistance; Replacement Parts; Accessories - Whirlpool YJMV9196CS Instructions D'utilisation

Masquer les pouces Voir aussi pour YJMV9196CS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Recommended Vent Length
A 3
" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round
1
4
vent should be used.
The total length of the vent system including straight vent,
elbow(s), transitions and wall or roof caps must not exceed
the equivalent of 140 ft (42.7 m) for either type of vent. See
the "Recommended Standard Fittings" section for equivalent
lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the
equivalent lengths of each vent piece used in the system.
See the following examples:
3
" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m)
1
4
total
A
2 ft
(0.6 m)
3
"
1
A. One
x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
4
B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
Call your authorized dealer or service center. When you call, you
will need the microwave oven model number and serial number.
Both numbers can be found on the model and serial number
plate, which is located behind the microwave oven door on the
front frame of the microwave oven.
If you need additional assistance, call us at our toll-free number
or visit our website listed in the User Guide.

Replacement Parts

If any of the installation hardware needs to be replaced, call us at
our toll-free number listed in the User Guide.
Following is a list of available replacement parts. You will need
your model and serial numbers located on the front facing of the
microwave oven opening, behind the door.
Damper Assembly
Mounting Plate
Upper Cabinet Template
Mounting Screw Kit (includes parts A-G in "Parts
Supplied" in the "Tools and Parts" section)
B
6 ft (1.8 m)
C

ASSISTANCE

6" (15.2 cm) vent system = 73 ft (22.2 m) total
A
2 ft
(0.6 m)
C
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1 rectangular-to-round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
If the existing vent is round, a rectangular to round transition
piece must be used. In addition, a rectangular 3" (7.6 cm)
extension vent between the damper assembly and rectangular to
round transition piece must be installed to keep the damper from
sticking.

Accessories

Filler Panel Kits are available from your dealer to use when
installing this microwave oven in a 36" (91.4 cm) or
42" (106.7 cm) wide opening. The filler panels come in pairs.
Each panel is 3" (7.6 cm) wide.
A. Filler panels
Filler Panel Kits:
See your authorized dealer or service center for details.
B
6 ft (1.8 m)
D
A
8171336 White
8171337 Black
8171338 Biscuit
8171339 Stainless Steel
99403 Almond
15

Publicité

Table des Matières
loading

Table des Matières