EQUIPMENT DESCRIPTION
DISPLAY UNIT
NORMAL DISPLAY
Output pressure indicator
During normal operation the pressure displayed on the
graphical bar occur between the pressure limits,
symbols
below the graphical bar.
Default pressure units are
is available. To change settings contact your service
representative.
Total operating hours indicator
Power / standby indicator
In run mode, the symbol permanently displayed.
In stand-by mode, the symbol flashed.
VISUAL ALARM SIGNALS
Low pressure
Signal is active, until the pressure is below the low
pressure limit.
Default value is 1,7 bar. Change of value is available.
To change settings contact your service representative.
High pressure
Signal is active, until the pressure is above the high
pressure limit.
Default value is 5,0 bar. Change of value is available.
To change settings contact your service representative.
High temperature
Signal is active if internal temperature rise above
65°C.
Loss of power
The signal is activated after a power loss. The device
automatically turns off after 5 minutes signal duration.
10
. Change of units to
BAR
NP-DK50 DI-17_03-2021
PSI