Siemens milltronics C-40 Manuel D'utilisation page 3

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Milltronics C-40 Solids Flowmeter
Milltronics C-40 solids flowmeter is a low- to medium-capacity flowmeter designed to
NFPA Code 8503 requirements for pulverized coal and coke. It is designed specifically for
applications where the possibility of material combustion or explosion exists. The C-40
flowmeter is equipped with an ILE-37 sensing head and is suitable for material flowrates
up to 40 t/h. The standard sensing head fiberglass cover is replaced by a hinged steel
cover.
The C-40 solids flowmeter is capable of containing an explosion generating an internal
pressure of 50 psi. Upset conditions generating up to 10 psi can be tolerated when a PTFE
inner gasket is used. In normal operation, the internal pressure must be less than 1 psig.
The flowmeter sensing head LVDT output signal is processed by the flowmeter integrator
(ordered separately) to:
monitor material flow
maintain accurate material inventory
The following components are included with each Milltronics C-40 flowmeter:
C-40 flowmeter housing and flowguide
ILE-37 sensing head (factory mounted)
spare damping fluid and filler bottle
To complete the Milltronics C-40 flowmeter system, the following parts must be ordered
separately:
stainless steel sensing plate
electronic flowmeter integrator
LVDT Conditioner Card in NEMA 4 enclosure
calibration weights
7ML19985DQ61
material
discharge
Milltronics C-40 – INSTRUCTION MANUAL
material infeed
flowguide
sensing plate
impact force
EN-1

Publicité

Table des Matières
loading

Table des Matières