Not all fumes are
being captured
Extraction
capacity too
low/non-existent
Dust escapes on
the clean air side
Product switches
off
NOTE
If the fault cannot be corrected by the customer, please contact the
manufacturer's service department.

7.6 Emergency measures

In case of fire of the product or its detection elements, the following steps
should be taken if necessary:
1. Where possible, disconnect the product from the power supply by
unplugging.
2. If present, disconnect the compressed air supply.
3. Fight fire with a commercially available dry powder extinguisher.
4. Notify local fire brigade if necessary.
WARNING
Do not open products with maintenance door. Flash flame formation!
In the event of a fire, do not touch the product under any circumstances
without proper protective gloves. Risk of burns!
1502518-00
Distance to welding point
too large
Throttle valve of the
extraction hood is closed
Clean air outlet obstructed Keep the clean air outlet
Filter element saturated
Rotation direction of the
fan is incorrect
Filter element damaged
Motor protection switch
has triggered
Tab. 33: Troubleshooting
- 98 -
Move the extraction hood
closer to the welding point
Open the throttle valve
opening clear
Change the filter element
Have a qualified electrician
swap two phases in the
CEE connector plug
Change the filter elements
Have the fan motor
checked by a qualified
electrician