VOLTCRAFT IR 1000-30D Notice D'emploi page 32

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Infrared temperature measuring range IR 1200-50D USB
Temperature measuring range:
- 50 to 20 °C
20 to 500 °C
500 to 1,000 °C
1000 to 1,200 °C
Infrared temperature measuring range IR 1600-50D USB
Temperature measuring range:
- 50 to 20 °C
20 to 500 °C
500 to 1,000 °C
1000 to 1,600 °C
Emissivity of different surfaces
The emissivity values stated in the table are approximations. Different parameters such as
surface geometry or quality can influence the emissivity of an object.
Surface
asphalt
concrete
ice
iron oxide
soil, humus
gypsum
glass/ceramic
rubber (black)
paints
32
All manuals and user guides at all-guides.com
Accuracy
± 4 °C
± 1.5 % of the measured ± 0.5 % of the measured value or ± 0.5 °C
value ± 1.5 °C
± 2 %
± 2.5 %
Accuracy
± 4 °C
± 1.5 % of the measured ± 0.5 % of the measured value or ± 0.5 °C
value ± 1.5 °C
± 2 %
± 2.5 %
Emissivity
0,90 – 0,98
0,94
0,96 – 0.98
0,78 – 0,82
0.92 – 0,96
0,80 – 0,90
0,90 – 0,95
0,94
0,80 – 0,95
Repeatability
± 1.5 °C
± 0.5 % of the measured value or ± 0.5 °C
± 1.0 % of the measured value
Repeatability
± 1.5 °C
± 0.5 % of the measured value or ± 0.5 °C
± 1.0 % of the measured value
Surface
paints (matte)
human skin
mortar
paper
plastic
sand
textiles
water
bricks
Emissivity
0,97
0,98
0,89 – 0,91
0,70 – 0,94
0,85 – 0,95
0,90
0,90
0,92 – 0,96
0,93 – 0,96

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ir 1200-50dIr 1600-50d10 09 1310 09 1410 09 16

Table des Matières