Bartscher 109.142 Mode D'emploi page 27

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Pag. 10
"Er.
Thermostop timeout
03"
"Er.
Tank loading
timeout
04"
"Er.
05
Open tank sensor
Er
06"
"Er.
07
Open boiler sensor
Er
.08"
"er
Too high tank
temperature
ht
"Er
Too high boiler
temperature
Hb"
"Er
Electromechanic
safety
sf"
"Er
Boiler loading
timeout
09"
"Er
Failed rinse cycle
01"
"Er
Level safety
SL"
Attempt to reset
"Er rb"
error 09
Tank thermostop
"Er 22"
timeout
"no
Salt missing
(warning)
ns"
"no
Detergent missing
dn"
(warning)
"no
Rinse aid missing
bn"
(warning)
"no
Softener service
na"
(warning)
"no
Break tank empty
(warning)
13"
USE AND MAINTENANCE MANUAL
The boiler temperature did not reach the set point within the extension of
the operating cycle washing phase. The boiler heating is disabled.
Contact the authorised service centre.
Water level inside the washing tank not reached. Turn the machine off
and on, make sure that the overflow pipes are fitted correctly and
that water supply is open, otherwise contact the authorised service
centre.
Broken tank sensor. The tank heating is disabled. Contact the
authorised service centre.
Broken boiler sensor. The boiler heating is disabled. Contact the
authorised service centre.
B4 > MaxTankTemp. The tank heating is disabled.
B2 > MaxBoilerTemp. The boiler heating is disabled.
It is likely that a safety thermostat has been triggered.
Turn the machine off and on; should the problem still occur, contact
an authorised service centre.
Problem with boiler water loading, make sure the water supply is correctly
open and that flow rate is suitable, according to machine nameplate
specifications. Turn the machine off and on; should the problem still
occur, contact the service centre.
The rinse cycle has not been correctly carried out, check that rinse
spraying nozzles are free from any obstruction.
Should the problem still occur, contact the service centre.
Problem with water drain. Drain electric pump has not drained correctly.
Check drain tubes; should the problem still occur, contact the service
centre.
The machine displays this message when attempting to solve boiler
Problem with boiler water heating. Contact a service centre.
Add salt in the relevant reservoir inside the washing tank
( machines with external water softener )
If this message is displayed quite often, make sure the water flow rate is
correct according to machine specifications.
Warning: By turning the machine off and on again, the warning
resets and thus, if the problem has not been solved, it will be
displayed again.
loading problem.
( machines with water softener )
Carry out resin reconditioning.
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

109.143