Water Application Functions - Danfoss VLT AQUA Drive FC 202 Guide De Programmation

Masquer les pouces Voir aussi pour VLT AQUA Drive FC 202:
Table des Matières

Publicité

Listes des paramètres

4.1.24 29-** Water Application Functions

Numé
Description du paramètre
ro de
param
ètre
29-0* Pipe Fill
29-00
Pipe Fill Enable
4
4
29-01
Pipe Fill Speed [RPM]
29-02
Pipe Fill Speed [Hz]
29-03
Pipe Fill Time
29-04
Pipe Fill Rate
29-05
Filled Setpoint
29-06
No-Flow Disable Timer
29-07
Filled setpoint delay
29-1* Deragging Function
29-10
Derag Cycles
29-11
Derag at Start/Stop
29-12
Deragging Run Time
29-13
Derag Speed [RPM]
29-14
Derag Speed [Hz]
29-15
Derag Off Delay
29-16
Derag Counter
29-17
Reset Derag Counter
29-2* Derag Power Tuning
29-20
Derag Power[kW]
29-21
Derag Power[HP]
29-22
Derag Power Factor
29-23
Derag Power Delay
29-24
Low Speed [RPM]
29-25
Low Speed [Hz]
29-26
Low Speed Power [kW]
29-27
Low Speed Power [HP]
29-28
High Speed [RPM]
29-29
High Speed [Hz]
29-30
High Speed Power [kW]
29-31
High Speed Power [HP]
29-32
Derag On Ref Bandwidth
29-33
Power Derag Limit
29-34
Consecutive Derag Interval
29-35
Derag at Locked Rotor
29-4* Pre/Post Lube
29-40
Pre/Post Lube Function
29-41
Pre Lube Time
29-42
Post Lube Time
29-5* Flow Confirmation
29-50
Validation Time
29-51
Verification Time
29-52
Signal Lost Verification Time
29-53
Flow Confirmation Mode
29-6* Flow Meter
29-60
Flow Meter Monitor
326
®
VLT
AQUA Drive FC 202
Valeur par défaut
4-setup
[0] Désactivé
2 set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 s
All set-ups
0.001
ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
0 s
All set-ups
0 s
All set-ups
ExpressionLimit
2 set-ups
[0] Off
1 set-up
0 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
10 s
All set-ups
0 N/A
All set-ups
[0] Pas de reset
All set-ups
0 kW
All set-ups
0 hp
All set-ups
200 %
All set-ups
601 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5 %
All set-ups
3 N/A
2 set-ups
ExpressionLimit
All set-ups
[0] Désactivé
All set-ups
[0] Disabled
All set-ups
10 s
All set-ups
10 s
All set-ups
ExpressionLimit
All set-ups
15 s
All set-ups
1 s
All set-ups
[0] Confirmation
Only
All set-ups
[0] Disabled
All set-ups
Danfoss A/S © 05/2018 Tous droits réservés.
Modification en
Indice de
cours de
conversion
fonctionnement
FALSE
-
TRUE
67
TRUE
-1
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-2
TRUE
-1
FALSE
0
TRUE
-
TRUE
0
TRUE
67
TRUE
-1
TRUE
0
TRUE
0
TRUE
-
TRUE
1
TRUE
-2
TRUE
0
TRUE
0
TRUE
67
TRUE
-1
TRUE
1
TRUE
-2
TRUE
67
TRUE
-1
TRUE
1
TRUE
-2
TRUE
0
FALSE
0
FALSE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
-2
TRUE
-2
TRUE
-2
FALSE
-
TRUE
-
Type
Uint8
Uint16
Uint16
Uint32
Int32
Int32
Uint32
Uint16
Uint32
Uint8
Uint16
Uint16
Uint16
Uint16
Uint32
Uint8
Uint32
Uint32
Uint16
Uint16
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint32
Uint32
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint32
Uint32
Uint32
Uint8
Uint8
MG20OB04

Publicité

Table des Matières
loading

Table des Matières