CB36, CB40
Key for fig. 3, page 3
Co-ordinate axis
l
A
NOTICE!
Make sure that the polarity is correct.
2. Connect the red lead to the positive terminal.
3. Connect the black lead to earth.
4. Before starting up the device for the first time, check whether the operating volt-
age and the battery voltage correspond (see type plate).
5. Connect the refrigerator
– As directly as possible to the pole of the battery or
– To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at 24 V).
A
NOTICE!
Disconnect the refrigerator and other power consuming devices from
the battery before connecting the battery to a quick charging device.
Over voltage can damage the electronics of the device.
The refrigerator is equipped with an electronic device to protect against reversing
the polarity and short circuits when connecting to a battery.
To protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Switch-off voltage
Switch-on voltage
EN
Installing and connecting the refrigerator
Meaning
Cable length
Cable cross section
12 V
10.4 V
11.7 V
Unit
m
mm²
24 V
22.8 V
24.2 V