INFOSEC UPS SYSTEM E4 EVOLUTION II+TT Serie Mode D'emploi page 105

Table des Matières

Publicité

LV MODEL (208V)
CAPACITY*
INPUT
Voltage
Low Line Loss
Range
Low Line Comeback
High Line Loss
High Line
Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Phase
Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Frequency Range (Batt. Mode)
Overload
AC mode
Battery mode
Current Crest Ratio
Harmonic Distortion
Transfer
Line
Battery
Time
Inverter
Bypass
Inverter
EFFICIENCY
AC mode
Battery Mode
BATTERY
Standard
Type
Model
Numbers
Recharge Time
Charging
Current(max.)
Charging Voltage
Long-run
Type
Model
Numbers
Charging
Current(max.)
Charging Voltage
PHYSICAL
Standard
Dimension,
Model
D X W X H
mm
Net Weight (kgs)
Long-run
Dimension,
Model
D X W X H
mm
Net Weight (kgs)
ENVIRONMENT
Operation Temperature
Operation Humidity
Operation Altitude**
INFOSEC UPS SYSTEM – 15, rue du Moulin – 44880 Sautron – France – www.infosec-ups.com
104
hotline : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – hotline@infosec.fr – 07 19 AA 59 205 03
E4
Evolution II +
10k TT
(S)
10KVA
10KW
100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately
100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately
≦ 2 % @ 100% Linear Load; ≦ 4 % @ 100% Non-linear Load (PF≥0.8)
0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
ECO
12 V / 9 Ah
(8+8)pcs
9 hours recover to 90% capacity
1.0~12.0A±10% (Adjustable)
1.0~12.0A±10% (Adjustable)
626 x 250 x 750
139/141
626 x 250 x 750
43/45
0 ~ 40°C (the battery life will down when > 25°C)
E4
E4
Evolution II
Evolution II
+ 15k TT
+ 20k TT
(S)
(S)
15KVA
20KVA
15KW
20KW
70 VAC(Ph-N) ± 3 % at 50% Load
88 VAC(Ph-N) ± 3 % at 100% Load
Low Line Loss Voltage + 5V
156 VAC(L-N) ± 3 % at 50% Load
146 VAC(L-N) ± 3 % at 100% Load
High Line Loss Voltage - 5V
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
3 Phase with Neutral
≧ 0.99 at 100% Load
3 Phase with Neutral
208/220VAC (Ph-Ph)
120/127VAC (Ph-N)
± 1%
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
3:1 max
0 ms
<10 ms
93.5%
92.5%
12 V / 7 Ah
12 V / 9 Ah
(8+8)pcs x 2 strings
+/-109 VDC ± 1%
Depending on applications
16 ~ 20 (adjustable)
+/- 13.65 VDC * N ± 1% (N = 8~10)
815 x 300 x
815 x 300 x
1000
1000
152
117
815 x 300 x
815 x 300 x
1000
1000
60/65
61/71
<95 % and non-condensing
<1000m**
E4
E4
Evolution
Evolution II
II + 30k TT
+ 40k TT
S
S
30KVA
40KVA
30KW
40KW
N/A
2.0~24.0A±10% (Adjustable)
N/A
790 x 360 x
790 x 360 x
1010
1010
108/112
113/117