Pc1616/1832/1864 Programming - DSC GS2060 Manuel D'installation

Masquer les pouces Voir aussi pour GS2060:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. To wire the Communicator to the panel, perform the following (See Figure 3).
WARNING!
All
connections
TL260GS/GS2060
module
limited. Do not route any wiring over the
circuit boards. Maintain at least 1"
(25.4mm) separation between circuit
board and wiring. A minimum of 1/4"
(7mm) separation must be maintained at
all points between non-power limited
wiring and power limited wiring.
PC1616/1832/1864
NOTE: For more details, refer to the
control, panel Installation Manual.
AUX+
BELL+
AC AC
RED BLK YEL GRN
AUX-
BELL-
a. Disconnect the AC power and the battery + connections from the panel.
b. Attach a wire from the Communicator's left PWR terminal to the panel's BELL+ terminal.
NOTE: For ULC Commercial Fire Monitoring applications, do NOT connect any devices on the Bell+
terminal other than the GS2060/TL260GS.
c. Attach a wire from the Communicator's GND terminal to the panel's AUX - terminal.
d. Attach a wire from the Communicator's SHLD terminal to the panel's EGND terminal. (Protective earth
ground).
e. If a Bell/Siren is used, attach a wire from the Communicator's right PWR terminal to the positive (+) termi-
nal on the Bell/Siren. (See Figure 3).
f. If a Bell/Siren is used, attach the panel's BELL - terminal to the negative (-) terminal on the Bell/Siren.
NOTE: If a Bell/Siren is not used, install the 1K
plied with the panel) between the panel's Bell + and Bell - terminals, then only wire the BELL + to
the PWR terminal on the Communicator.
g. Confirm that the SIM card is inserted and locked. (See
h. Insert the PC-LINK connector into the Communicator's PC-LINK socket. (Black wire on Pin 1 on the
Communicator).
i. Route the CAT 5 Ethernet cable through back of the cabinet and plug it into the Communicator's RJ45
jack.
NOTE: Before leaving the premises the Ethernet communication lines must first be connected to an
approved (acceptable to local authorities) type NID, (UL installations, UL 60950 listed NID, for ULC
installations CAN/CSA C22.2. No. 60950-1 Certified NID).
4. Perform the following for initial power on of the panel with Communicator installed:
a. Reconnect the AC power and battery + connector to the panel. (the Communicator and Panel will power
up together).
b. Observe that the Communicator's red and yellow LEDs are flashing together while it initializes. The red
and yellow LEDs will continue to flash until the unit has successfully communicated to all programmed
receivers. If this is the first time the Communicator has been powered up, the module will request pro-
gramming from Connect24.
c. At the keypad, enter [*][8][Installer Code][382] and confirm that Toggle Option [5] is ON (GPRS/Ethernet
Module Enabled).
NOTE: Initialization may take several minutes to complete. Red and yellow LEDs will flash together
during initialization. Do not leave the installation until the red and yellow LEDs have stopped flash-
ing. (If only the yellow LED is flashing, there is a Communicator trouble and the Green LEDs are not
valid for Communicator Placement Test). Correct trouble before continuing. (See Table 6 for trou-
bleshooting assistance).
5. Perform the Communicator Placement Test on page 8.

PC1616/1832/1864 Programming

Perform the following steps to ensure that the Communicator and the panel work together as intended.
These Sections must be programmed at the panel keypad. Enter [*][8][Installer Code][Section Number]. Record
any values that are modified from their default, in the appropriate Worksheets for the Panel or Communicator.
NOTE: The toggle is ON when the number is displayed. Toggle is OFF when the number is not dis-
played. (e.g., [1---5---], Toggle Options 1 and 5 are ON, all others are OFF). Press the number on key-
pad to turn toggle ON/OFF.
to
the
are
power
UA503
PGM1
PGM3
Z1 COM Z2
Z3 COM Z4
PGM2
PGM4
Figure 3 GS2060/TL260GS Wiring Diagram
To external
antenna
L
o
GSM Radio
c
k
SIM Card
Holder
Hardware
Default
PWR PWR GND GND
PC-LINK
1
Black
Black
1
CON 4
PC-LINK
RING
R-1
Z5 COM Z6
Z7 COM Z8
EGND
TIP
T-1
½ W 5% resistor (Brown, Black, Red, Gold) (sup-
Inserting and Removing the SIM Card on page 3
5
TL260GS / GS2060
Status
LEDs
GND
SHLD
Network Connection
(Model TL260GS)
Use only CAT5 cable
(300ft/100m max.) Supervised
Input Ratings (from Bell Out)
11.1V - 12.6 V
100mA standby; 400mA Alarm
DSC Panel minimum
power requirements
16 V
40 VA transformer
AC
12 V
7Ah battery
DC
+
+
-
-
External Bell/Siren
DC
).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tl260gsGs2065Tl265gs

Table des Matières