3) Once separated from the chassis, wash the base by hand by filling with water
and adding 8 oz. of white vinegar. Let solution set for 20 minutes, then empty
and rinse thoroughly.
4) Similarly, clean the bottle by filling with water and 8 oz. of white vinegar, then
allow to set for 20 minutes. Rinse thoroughly.

DISINFECTING UNIT

5) Fill the base and bottle ½ full with water and add 1 teaspoon of bleach. Let
solution stay for 20 minutes, then rinse with water until bleach smell is gone.
Dry interior surfaces with clean cloth. Wipe down the outside of the unit with
a soft cloth dampened with fresh water.
6) Refill unit and reassemble per ASSEMBLY instructions.

SUMMER STORAGE

1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wick and any water in the reservoir. Allow to dry thoroughly
before storage. Do not store with water inside reservoir.
3) Do not store unit in an attic or other high-temperature area, as damage is probable.
4) Install new filter at beginning of season.