CONTROL LOCK FEATURE
the control will resume the display of the room humidity. The humidifier will
continue to function with the locked in settings. If buttons are operated while "CL"
is active, the "CL" is displayed and settings are unaffected.
DEACTIVATION PROCEDURE
To deactivate the "CL" function simply press and hold both buttons for 5
seconds. "CL" will flash at the rate of 1 second on and 1 second off for a period
of 2 seconds and then resume the display of room humidity.
REPLACEMENT OF WICK
CAUTION: Before changing wick, ensure unit is turned
OFF and unplugged.
NOTE: This unit uses model SGL1040 wick. Replace the wick
at the beginning of each season, and more often in areas with
hard water.
1) To replace wick, remove the water bottle and set aside in
a safe place.
2) Reach in and remove the old wick and replace with a fresh wick.
3) Replace water bottle

CARE AND MAINTENANCE

Cleaning your humidifier regularly helps eliminate odors and bacterial and
fungal growth. Ordinary household bleach is a good disinfectant and can be
used to wipe out the humidifier base and bottle/reservoir after cleaning. We
recommend cleaning your humidifier whenever changing the
recommend using Essick Air
humidifier to eliminate bacterial growth. Add bacteriostat according to the
instructions on the bottle. Visit www.aircareproducts.com or call 1-800-547-3888
to order Bacteriostat Treatment, part number 1970.
STANDARD CLEANING
1) Turn off unit completely and unplug
from outlet.
2) Remove water bottle from the
humidifier and place it in a secure
place. Remove and dispose of used
wick. Locate the two internal spring
latches on the front and rear of the
base. Releasing these latches will
allow removal of the top housing. Flex
the rear latch and lift the back of the
top housing off the base far enough to clear the latch. Flex the front latch and
lift the complete top housing away from the base. Place the top housing on a
flat surface.
To avoid unwanted tampering with the humidifier settings the
controls can be locked.
ACTIVATION PROCEDURE
After the humidifier functions have been set up, hold the
Speed and Humidity buttons down for 5 seconds. The display
will show "CL" for 2 seconds; release the power button and
.
®
Bacteriostat Treatment each time you refill your
7
wicks.