• Select a proper "FINE" phase so that the two video signals on the oscilloscope come as close as possible.
Notes:
• Moving the "I" cursor across the +/- end will shift the "FINE" range.
• Press the [LEFT] and [RIGHT] buttons simultaneously to reset the "V PHASE" to the default (0 degree).
• Keep pressing the [LEFT] and [RIGHT] buttons for a second to move the "I" cursor faster if necessary.
• Spike noise if contained in the AC mains may disturb synchronization of LL.

7. White Balance Setting (WHITE BAL)

Select a mode for "WHITE BAL" on the "CAMERA SETUP" menu. The default setting is "ATW1".
ATW1: Is automatically adaptable to the color temperatures of 2 700 K - 6 000 K.
ATW2: Is automatically adaptable to the use of sodium lamps (2 000 K - 6 000 K).
AWC: Is automatically adaptable to the color temperatures of 2 000 K - 10 000 K.
Notes:
• When "ATW1" or "ATW2" is selected, no further operation is required.
• "ATW1" and "ATW2" do not appear on the setup menu of the system controller.
• Select "AWC" in the following cases: the color temperature is out of the 2 000 K - 6 000 K range, the scene contains mostly
high color temperatures such as blue sky or sunset, or the scene is dim.
• When "AWC" is selected, the "AWC" setting is required.
AWC Setting
1. Select "AWC" and press the [LEFT] button.
→ "AWC" will change to "AWC → PUSH SW".
2. Press the [SET] button.
→ "PUSH SW" will be highlighted while the "AWC" setting is
performed.
Note:
• If the white balance is not set, "PUSH SW" is being highlighted.
3. Press the [RIGHT] button.
Manual Fine Adjustment
Perform fine adjustment as necessary.
1. Select "WHITE BAL" and press the [SET] button.
→ Fine adjustment menu of ATW or AWC will open.
2. Adjust finely "R" (Red) and "B" (Blue) gain by moving the "I" cursor.

8. Motion Detection Setting (MOTION DET)

When a series of changes in pictures is detected, the camera out-
puts an alarm to the external device such as a disk recorder. The
recorder will start recording the pictures.
1. Select a mode for "MOTION DET" on the "CAMERA SETUP"
menu.
The default setting is "OFF".
OFF: Disables the alarm output.
MODE1: Outputs alarm when a series of motions is detected.
MODE2: Outputs alarm when a series of scene changes is
detected.
→ The "MODE1" menu opens when you select "MODE1" and press the [SET] button.
2. Adjust for "LEVEL" to optimize the sensitivity of detection.
**ATW1**
R
···I···129
-
+
B
···I···127
-
+
RET TOP END
**MODE1**
LEVEL
······I255
-
+
DWELL TIME
2S
O
DISPLAY MODE
ALARM
OFF
O
MASK SET
RET TOP END