Choosing a location

Choosing a location
Fig. 2
RM
RM
Bedroom
RM
Children`s room
Living room
RM
RM
RM
Kitchen
Boiler /
utility room
RM
RM
Work room /
workshop
Smoke alarms should be regarded as a minimum level of equipment
sleeping rooms, children's rooms and corridors or passages used as escape routes;
one alarm should be fitted in the centre of each room, always on the ceiling (no wall
mounting) (Fig. 2). Select the highest point in the room for mounting, with a mini-
mum distance of 50 cm from any wall, furniture or lamps. Your installation is
optimised
by also installing the devices in all other rooms as well as on all
RM
landings. A smoke alarm is not normally required in washrooms (bathroom,
WC etc.) owing to the low fire risk in these rooms.
Please observe the illustrations in this manual!
The smoke alarm should not be installed in the following areas
• outside (use only in enclosed spaces);
• in areas in which the alarm can be triggered by disturbances (steam,
condensation, 'normal' smoke, fumes, dust, dirt or grease);
• next to ventilation or similar air inlets (draughts);
• in areas where temperatures may fall below 0° C or exceed 45° C.
RM
RM
Bedroom
Bathroom
RM
RM
RM
RM
Children's
Children's
RM
room
room
– 26 –

Installation and operation

Installation and operation
In order to mount the alarm on the ceiling,
follow the steps in the order listed below:
1. Remove smoke alarm from the cover base
RM
by turning anti-clockwise.
Kitchen
2. Remove the locking pin located in the
mounting socket (further use in step 7,
is used for unintentional disassembly).
RM
3. Mark the holes through the cover base.
Living room
4. Fit the required rawlplug into the drill hole
and tightly screw in the detector base.
in all
RM
When marking out your drill holes, ensure that no electrical wires
cables, pipes or other installation components are located behind
the installation point!
5. Then enter the current date (installation date)
on the label on the reverse side of the alarm
with a water and abrasion resistant pen
(see illustration opposite).
6. Attach smoke alarm by turning clockwise at the
detector base. Small markings are found on the
side of the detector base and on the alarm itself
which make it easier to fit the alarm onto the base.
7. Insert the locking pin from step 2 into the designated side opening
to prevent the alarm from turning (see next illustration).
2.
2.
Installationsdatum | Installation date | Date
d'installation: _____________ (DDMMYYYY)
z. B. : 09|05|2016
– 27 –