Produktgruppe 512
9 von 48
Danger!
Correct earthing function can be deactivated if casing parts are incorrectly assembled.
Correct earthing function must be ensured when refitting the casing.
Carry out appropriate electrical safety checks.
Danger!
During fitting, all accessible conductive parts that are not connected to the earth must not have any link to earth (strengthened double
insulation).
To confirm this, insulation resistance and touch current measurements must be carried out.
Note
The kit, Mat. no. 09079470, for PW 6107, PW 6137, PW 6167 and PW 6207 contains the following:
1 electronic module EZL 235, module 5 (liquid dispensing 1 - 3 and WRG (water recycling))
4 spacers (for electronic module EZL 235 fastening)
1 coding plug MFM 1-2-5 (module 5 EZL 235 - Plug connector ST3), PIN 1-2-5
1 coding plug WRG 1 (module 5 EZL 235 - Plug connector ST6), PIN 2-3
1 coding plug MFM 53X (module 5 EZL 235 - Plug connector ST7), PIN 1-2, 3-4
1 coding plug 40X (module 5 EZL 235 - Plug connector ST14), PIN 1-4
1 plug N1Q_ST11A (module 5 EZL 235 - Plug connector ST11), PIN 1-2
1 wiring harness 20X-41X (module 5 EZL 235 - Plug connector ST10 / ELP 235 - Plug connector ST14), plug housing, 3-pole,
720 mm
1 wiring harness N1D_ST13, X3-4 (module 5 EZL 235 - Plug connector ST13 / Terminal strip X3-4), plug housing, 3-pole, 350 mm
1 wiring harness N1Q_ST11, Y39 (module 5 EZL 235 - Plug connector ST11 / Intake valve Y39), plug housing, 2-pole, 1050 mm
1 wiring harness N1L_ST11B, N1Q_ST11 (module 5 EZL 235 - Plug connector ST111 / ELP 235 - Plug connector ST11B), plug
housing, 4-pole, 650 mm
1 connection wire - Blue 0.75 x 280
Note
The kit, Mat. no. 09079470, for PW 6107, PW 6137, PW 6167 and PW 6207 also contains the following:
2 bolts M4 x 12.5
1 intake valve 3/4", cold water
1 sticker
1 hose
2 hose clips 8 - 16 mm
1 screw connector strip, 4-pole, neutral
1 screw connector strip, 4-pole, red
1 screw connector strip, 6-pole, blue
1 screw connector strip, 7-pole, green
1 terminal strip 1X3-4, orange
1 terminal strip 2X3-4, grey
1 terminal strip 3X3-4, blue
1 terminal strip 4X3-4, green/yellow
1 flat plug, 4-pole (dispenser pump earth)
1 liquid dispensing accessory
1 wiring diagram PW 6107 - PW 6207 module 5, Mat. no. 09021450
Fitting instructions - Module 5, liquid dispensing 1 - 3 and water recycling (WRG), Mat. no. 09081940.
List of illustrations:
Fig. 1: Fitting electronic module EZL 235
Fig. 2: Fitting intake valve on connection strip
Fig. 3: Connecting electronic module EZL 235, module 5, liquid dispensing 1 - 3 and water recycling (WRG)
Fig. 4: Fitting cable throughfeed on connection strip
Disconnect the machine from the gas (if applicable) and electric mains and ensure utilities cannot be switched on again in error.
Remove the screws on the left and right of the top of the lid.
10.02.2012