Manufacturer's recommendations:
° Clean the lamp with a clean dry cloth, before mounting it into place.
° Positioning of the lamp and connecting of the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free from dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transported.
° The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
° It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather
Technical characteristics:
Nominal absorbed voltage ................................................................................. 1200 Watts
Voltage use: European standard ........................................................... 220/240 Volts 50Hz
Voltage use: North American standard ......................................................... 208Volts 60Hz
Minimum voltage of the power supply .................................................................... 198Volts
(Below this charge = ignition failure is possible).
Voltage at the terminals of the lamp ...................................................................... 100 Volts
Amperage at the terminals of the lamp ............................................................... 13,8 Amps
Luminosity of the lamp ...................................................................................... 110 000 L's
Luminous effectiveness ...........................................................................................92 Ln/W
Colour temperature .......................................................................................... 5600 ° Kelvin
Base ................................................................................................................... SFa 15,5-6
Theoretic duration of lamplife ............................................................................... 750 hours
User's precautions:
° The lamplife, as given by the manufacturer, is an theoretic lamplife duration as "in laboratory conditions" a cycle
based on 3 hour's alight / 1 hour off, cycles more brief, reduce the duration of the lamplife.
° In operating conditions it is uncommon for the lamp to be still working after 200 to 300 hours. Its efficiency can
decrease 30%.
° Premature wearing of lamp under performing conditions, is mainly due to frequent switching on. Better to leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lampelife is reduced about
1 hour, each time the lamp is lighten ).
° Theoretically the lighting unit is designed for instant restrike, but it is still advised to wait for 10 minutes before
switching on again. ( This extends the duration of the lamp.)
° Use over 500 hours of the lamp : change the lamp even thou it still lights up.
A new lamp:
° To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
° Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event of a dispute.
9
robert juliat
TECHNICAL FILE
HMI 1200 FOLLOWSPOT

ADMISSIBLE LAMPS :-

OSRAM: HMI 1200W/GS
PHILIPS: MSI 1200
Thank you.
1011
1011
A DATER DU:
VALID SINCE:
ROUTE DE BEAUMONT F 60530 FRESNOY - EN - THELLE
TEL.: 33 (0)3.44.26.51.89
FAX : 33 (0)3.44.26.90.79
+
+
B
08.12.97

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b

Table des Matières