Robert Juliat 1011+ Dossier Technique page 14

Masquer les pouces Voir aussi pour 1011+:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

robert
juliat
CONNECTIONS.
g
Mains voltage.
- Refer to the previous page.
Lighting unit / Power supply connection.
- Connect the Lighting unit/Power supply cable C by passing it
inside the yoke.
- Leave a little slack and then block the cable C into the lock g .
- Place the lamp into position - refer to page 8.
- Connect the cable
ballast and to the connector
- Connect the fan's power cable
220/240V. j , by passing it through clip h .
- Connect the DATA line on connector ( a ) "XLR5" or the analog
command E to the the connector ( c ) "XLR4".
( For the connection configurations : refer to page 12 ).
- Plug the cable
8
the checklight 1
lights up immediately.
- Engage the circuit breaker
protection 4
( fuse ) is well engaged.
- If you use the optional outlet 5 , engage the circuit breaker 2 .
NOTE : The optional outlet 5 is not cut by breaker 3 , this
allows the use of accessories when the lighting unit is not
powered.
CAUTION - For your security !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when bulb is in place.
7
robert juliat
HMI 1200 FOLLOWSPOT
A
i
j
F
D
to the connector ( d ) of the
k of the lighting unit "XLR7".
F
to the mains output
to the mains. If the power is present,
3 and check that the CAD 900
TECHNICAL FILE
k
h
E
C
B
11
DESCRIPTION.
A 1011+ B. Motorized shutter - CAD 900 version.
i - EM HARTING 16 x 16A power socket.
j - EF mains output 220/240V (fan).
k - EM XLR7 shutter + DATA.
B Power supply unit.
1 - Mains checklight.
2 -
Ballast/lantern
3 - General 16A circuit breaker.
4 -
Ballast/lantern
5 - Double socket 10/16A (direct).
6 - Ventilation opening
7 - EF HARTING 16 x 16A - 2 latch connector.
8 - Mains cable 3G x 1,5mm (2,5m)+FM 10/16A.
9 - CAD 900 local controls.
10 & 11 - Rating plate.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm length 3m fitted
with 16 x 16A M/F HARTING connectors.
D Shutter cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
E Analog fader control.
Shielded cable - length 3m fitted with a XLR4
female connector.
F Fan's power cable.
3 x 0,75 mm cable L = 105 cm fitted with a
220/240V EEC male connector.
A DATER DU:
VALID SINCE:
D
9
6
3 4
2
1
7
5
10
8
DATA Line.
PC Aux. protection
PC Aux. protection
(DON'T OBSTRUCT THE AIR GAPS).
2
C A D 900
0/10V - DMX 512 - AVAB
a - EM XLR5 : DATA input.
b - EF XLR5 : DATA output.
ERROR
SELECT
EXIT
+
DATA
EXT. DIGI.
LOCK
EXT.
LOCAL
c - EM XLR4 : 0/+10V. input.
RESET
a b c d
d - EF XLR7 : lighting unit output.
DATA
0/10V
CONTROL
SHUTTER
2
2
ROUTE DE BEAUMONT F 60530 FRESNOY - EN - THELLE
TEL.: 33 (0)3.44.26.51.89
+
1011
+
1011
B
+
1011
B
08.12.97
DATA
DMX 512 Line.
(fuse 10,3 x 38 2A Gg).
(fuse 10,3 x 38 2A Gg).
FAX : 33 (0)3.44.26.90.79

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b

Table des Matières