Never stand on the top cover of the appliance or place heavy objects on it, as
this could cause damage to property and/or personal injury.
Installation must be carried out by persons qualified to do so. Damage to
property and/or personal injury may occur if the installation is not carried out
by qualified persons.
The regulations for electrical safety must be taken into account when
installing the unit.
Ensure that power supply switches and circuit breakers are installed and used
in accordance with local safety regulations.
Install a circuit breaker. If you do not install a circuit breaker, the unit may
malfunction.
An all-pole circuit breaker, with a distance of at least 3 mm between the poles,
should be installed in the fixed wiring.
The appliance should be fully earthed. Insufficient earthing can lead to a risk
of electric shock.
Only use the power cord that is recommended by the manufacturer.
Make sure that the power supply meets the requirements of the appliance.
Insufficient power supply or incorrect wiring may cause malfunction of
the appliance. Install the correct power cables and cords before using the
appliance.
Connect the current-carrying wire, the neutral wire and the earth wire
correctly.
Make sure that you disconnect the unit from the power supply before carrying
out any electrical work.
Do not insert the power cord of the appliance into the wall socket until the
installation is complete.
If the power cord is damaged, it must be replaced by the manufacturer,
customer service or a similarly qualified person to avoid danger.
The temperature of the refrigerant circuit will be high. Keep the connection
cable away from the copper pipes.
The appliance must be installed according to the national wiring regulations.
The air conditioner is a high quality electrical appliance. It must be earthed by
a qualified person using a special earthing device. Always make sure that the
earthing has been done correctly, otherwise there is a risk of electric shock.
The yellow-green cable of the air conditioner is the earth cable and must not
be used for other purposes.
The earthing resistance should comply with national electrical safety
regulations.
The appliance must be installed so that the power cord is easily accessible.
All cables and wires of the appliance should be connected by a qualified
person.