OVEN CONTROL SETTINGS AND ADJUSTMENTS
Test Point Pressure
The oven burner pressure test point is located also on the manifold test point on the top section. The test point
pressure is shown in the Nominal Gas Consumption Table.
7.5

CONVERSION INSTRUCTIONS

ENSURE GAS IS ISOLATED WHILE PERFORMING CONVERSION WORK.
PERFORM A LEAK TEST BEFORE IGNITING AND CALIBRATING BURNER
TO PROPANE GAS
Regulator
Open Burner/Grill Burner
Oven Burner
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust.
AMEND DATA PLATE AND APPLY 'PROPANE' GAS LABEL
TO NATURAL GAS (NG)
Regulator
Open Burner/Grill Burner
Oven Burner
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust
AMEND DATA PLATE AND APPLY 'NATURAL GAS' LABEL
SPARE PARTS
A list of major spare part items is shown at the end of this manual.
TO BE COMPLETED BY AN AUTHORISED PERSON
AND PILOT ADJUSTMENTS.
Change regulator to PROPANE gas configuration and adjust as necessary
Access and change the injectors to PROPANE Gas injectors
(refer Nominal Gas Consumption Table)
Access and change the injector to a PROPANE Gas Injector
(refer Nominal Gas Consumption Table)
Change regulator to NG gas configuration and adjust as necessary
Access and change the injectors to a NG Injectors
(refer Nominal Gas Consumption Table)
Access and change the injector to a NG Injector
(refer Nominal Gas Consumption Table)