TROUBLEHOOTING

Digital display not illuminated.
Fan not operating (digital display
is illuminated).
Unit does not operate on any
speed setting
Motor does not turn on.
Not enough humidity
Too much humidity.(Condensation
develops on cold surfaces)
Water leak
Odor
Control panel does not respond to
input.Display shows CL
Display flashes "20"
Display flashes "—"
• No Power.
• Power button has not been
• ROOM humidity level is not
3% or more below SET
humidity level.
R
i i
• No power to unit.
• Unit has run out of water –
fan will not operate without
water is present.
• Refill switch
operation/improper
positioning of float assy.
If unit has overheated, motor
temp- sensing fuse may have
tripped.
Wick may be installed incorrectly
Wick is old and ineffective.
Humidistat is not set high
Humidistat is set too high.
Cabinet may have been overfilled.
There is a safety overflow hole in
rear of cabinet.
Bacteria may be present.
• Press Humidity and Speed buttons
at same time for 5 seconds to
deactivate feature.
• ROOM Humidity is lower than 20%. • Will read actual humidity when
• Unit initiating.
• Room humidity is over 90%.
9
• Check 120 volt power source.
• Press power button once to turn on.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• Ensure polarized plug is fully
inserted in wall outlet.
• Refill reservoir.
• Ensure float assembly is correctly
positioned as described in water
filling.
• CAUTION: Do not touch the fan
when accomplishing this test, as
the motor may turn on.
• To test the motor, turn unit ON and
turn all knobs fully ON.
• Turn the chassis over and insert
finger into tab where float rod is
supposed to go. If fan turns on, the
fan and motor are working
correctly.
• Take unit to qualified service
technician. DO NOT ATTEMPT
electrical repairs yourself.
• Remove and reinstall wick
correctly.
• Replace wick when clogged or
hardened with minerals.
• Increase humidity setting on
control panel.
Reduce humidistat setting or
increase room temperature.
DO NOT OVERFILL cabinet. Correct
water level is indicated inside of cabinet
side wall.
• Clean and disinfect cabinet following
Care and Maintenance instructions.
• Add EPA registered Bacteria
Treatment according to instructions on
the bottle.
• It may be necessary to replace the
wick if odor persists.
• Control lock feature has been turned on
to prevent changes in settings.
level comes up to 25%.
• Room humidity will display after
initiation is complete.
• Will remain until humidity drops
below 90%.