Performance Data Sheet - Bosch B21CT80SNS Notice D'utilisation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance data sheet

Model: 9000 077 508, 9000 705 475 and 9000 225 170
Use Replacement Cartridge 9000 674 655
The concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and
Standard 53.
System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53
for the reduction of the claims specified on the Performance Data Sheet.
Capacity 739.68 Gallons (2,800 Liters)
Contaminant Reduction Determined by NSF testing.
Contaminant
Average
Reduction
Influent
Chlorine Taste
2.1 mg/L
and Odor
Nominal
9,100,000
Particulate
pts/mL
Class I,
w 0.5 to < 1.0
μm
Cysts *
170,000
cysts/L
* Based on the use of Cryptosporidium parvum oocysts.
Application Guidelines/Water Supply Parameters
Service flow
0.75 gpm (2.83 lpm)
Water Supply
Potable Water
Water pressure
30 - 120 psi (207 – 827 kPa)
Water
33 °F - 100 °F (0.6 °C – 38 °C)
temperature
It is essential that the manufacturer's recommended
installation, maintenance and filter replacement
requirements be carried out for the product to perform
as advertised. See Installation Manual for Warranty
information.
Note: While the testing was performed under standard
laboratory conditions, actual performance may vary.
Replacement Cartridge: 9000 674655. For estimated
costs of replacement elements please contact your
local dealer or call 1-800-578-6890.
NSF specified
Avg %
Challenge
Reduction
Concentration
2.0 mg/L
97.6 %
±10 %
At least 10,000
98.8 %
particles/mL
Minimum
99.99 %
50,000 cysts/L
Average
Max
Product Water
Permissible
Concentration
Product
Water
Concen-
tration
0.05 mg/L
N/A
111,817 pts/ml
N/A
0.001 cyst/L
N/A
WARNING
To reduce the risk associated with ingestion of
contaminants:
DO NOT use this product with water that is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after
connection to the system. Systems certified for
cyst reduction may be used in disinfected water
that may contain filterable cysts.
EPA Establishment Number 10350-MN-005
NOTICE
To reduce the risk associated with property damage
due to water leakage or flooding:
Read and follow all Instructions before installation
and use of this system.
To reduce the risk of water leakage or flooding, and
to ensure optimal filter performance:
Change the disposable filter cartridge every six
months or sooner if you observe a noticeable
reduction in water flow rate.
Failure to replace the disposable filter cartridge at
recommended intervals may lead to reduced
filter performance and cracks in the filter housing,
causing water leakage or flooding.
en-us
NSF
NSF Test
Reduction
Report
Require-
ments
w 50 %
J-00121313
w 85 %
J-00099871
w 99.95 % J-00109715
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B21ct80snb

Table des Matières