Performance Data Sheet

Model 9000 7775078
Use Replacement Cartridge 9000 674655.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53.
System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of
the claims specified on the Performance Data Sheet.
Capacity 739.68 Gallons (2800 Liters)
Contaminant Reduction Determined by NSF testing.
Contaminant
Average
Reduction
Influent
Chlorine Taste and
2,1 mg/l
Odor
Nominal
9.100.000
Particulate
particles/ml
Class I, ≥ 0,5 to <
1,0 μm
Cyst*
170.00 cysts/l
Turbidity
11 NTU
* Based on the use of Cryptosporidium parvum oocysts
Application Guidelines/Water Supply Parameters
Service Flow
0,75 gpm (2,83 lpm)
Water Supply
Potable Water
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
0,6 °C - 38 °C (33 °F - 100 °F)
It is essential that the manufacturer's recommended installation,
maintenance and filter replacement requirements be carried out for the
product to perform as advertised. See Installation Manual for Warranty
information.
Note: While the testing was performed under standard laboratory
conditions, actual performance may vary.
Replacement Cartridge: 9000 674655. For estimated costs of
replacement elements please contact your local dealer or
call 1-800-578-6890.
m
Warning
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before and after the system.
Systems certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
EPA Establishment Number 10350-MN-005
3M is a trademark of 3M Company used under license.
NSF is a trademark of NSF International.
© 2013 3M Company. All rights reserved.
52
NSF specified
Avg %
Challenge
Reduction
Concentration
2,0 mg/l ± 10 %
97,6 %
Mind. 10.000
98,8 %
particles/ml
Minimum
99,99 %
50.000 cysts/l
11 ± 1 NTU
98,1 %
Average Product
Max
Water
Permissible
Concentration
Product Water
Concentration
0,05 mg/l
N/A
111.817
N/A
particles/ml
0,001 cyst/l
N/A
< 1 NTU
0,5 NTU
m
Caution
To reduce the risk associated with property damage due to water
leakage:
Read and follow Use Instructions before installation and use of this
system.
Installation and use MUST comply with all state and local plumbing
codes.
Do not install if water pressure exceeds 120 psi (827 kPa). If your
water pressure exceeds 80 psi, you must install a pressure limiting
valve. Contact a plumbing professional if you are uncertain how to
check your water pressure.
Do not install where water hammer conditions may occur. If water
hammer conditions exist you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check
for this condition.
Do not install on hot water supply lines. The maximum operating
water temperature of this filter system is 100 °F (38 °C).
Protect filter from freezing. Drain filter when temperatures drop
below 33 °F (0.6 °C).
The disposable filter cartridge must be replaced every 6 months, at
the rated capacity or if a noticeable reduction in flow rate occurs.
NSF
NSF Test
Reduction
Report
Requirements
≥ 50 %
J-00121313
≥ 85 %
J-00099871
≥ 99,95 %
J-00109715
≥ 95,5 %
J-00099885
Manufactured by:
3M Purification Inc.
400 Research Parkway
Meriden, Ct 06450
USA
Tel. (800) 222-7880
(203) 237-5541