2.
When a call for heat is received, the fireplace display panel
will illuminate and show the flame level.
MODE
SELECT
REMOTE
MANUAL
OFF
BLOWER
SPEED
DISPLAY
Mantis
BACK LIGHT
3.
Adjust flame level. If operating in thermostatic remote mode,
the flame level will adjust automatically.
The table below outlines the BTU input rate of the burner.
Flame Level
5
4
3
2
1
4.
The red and green control panel LED lights will begin to flash
alternately while the fireplace performs a safety test. After
approximately 45 seconds the test will complete and the
fireplace will prepare to ignite.
5.
After the safety test is complete, the ignitor will glow red and
the burner will light within approximately 30 seconds.
Note:
The startup sequence takes approximately 1 minute,
15 seconds to complete.
Note:
If the burner fails to light, the fireplace will retry the ig-
nition sequence three times then enter lock-out mode if it fails
to light. See page 19 for the fault codes and their meanings.
6.
After the burner lights, the flame icon on the display panel will
appear and the fireplace will automatically adjust to the flame
level shown on the display.
29432-1-0512
UP
MANUAL
FLAME LEVEL
ADJUSTMENT
FLAME
LEVEL
DOWN
UP
MANUAL
FLAME LEVEL
ADJUSTMENT
FLAME
LEVEL
DOWN
BTU Input
20,000
17,500
15,000
12,500
10,000
MODE
SELECT
REMOTE
MANUAL
OFF
BLOWER
SPEED
DISPLAY
Mantis
BACK LIGHT
Attention: The fireplace will always ignite on Level 5 (High)
prior to adjusting to the flame level shown on the display panel.
7.
The blower will activate after three to five minutes depending
on flame level. The blower will automatically adjust its speed
as the fireplace warms up or cools down. The blower speed
will be indicated on the display panel. See page 13.
8.
The flame level can be adjusted either up or down at any
point during the fireplace's operation. If using the remote's
thermostatic function, the fireplace adjusts the flame level
automatically.
Note: When changing from a low flame level to a higher flame
level, the fireplace will automatically increase to Level 5 (High)
prior to proceeding to the desired flame level. This is to ensure
consistent operation.
9.
When the fireplace is shut down, the inducer will operate
at full power for approximately 10 seconds after the burner
is extinguished. This is to clear any flue products from the
fireplace's combustion chamber. The circulating air blower
will continue to operate until the fireplace cools sufficiently.