Solids Applications – Typical
Applicable Transducers:
1
2
1. Transducer angled to avoid seams in bin wall and
aimed at discharge in order to read bin when empty.
2. Avoid intersecting bin wall seams, structural
members and wall irregularities. Otherwise, refer to
transceiver manual.
4
discharge
4. On fluid-like solids, aim transducer
perpendicular to material surface.
7ML19985HV61
• Echomax XPS/XCT series
• Echomax XRS-5 series
bin wall seams
filling profile
emptying profile
minimal angle
of repose
Transducers – APPLICATION MANUAL
• ST-H series
Easy Aimer
3. Transducer too close to material inlet.
Falling material will intersect sound
beam and cause erroneous readings or
loss of echo.
transducer
5. On dual discharge bins, aim each
transducer at the discharge point.