Table des Matières

Publicité

WET SCRUBBING

WET SCRUBBING
WET SCRUBBING
WET SCRUBBING
WET SCRUBBING
1 1 1 1 1
Follow the instructions in the Preparing The Machine For Use section of this manual.
2 2 2 2 2
Turn the Master Key Switch (B)
Hour Meter (A)
(A).
(A)
(A)
(A)
3 3 3 3 3
Release the Operator Hand Brake (16)
4 4 4 4 4
Press the Solution Button (D)
surface when starting to scrub with dry brushes.
5 5 5 5 5
Press the Scrub ON Button (G)
more detailed explanation of this and other control panel functions.
6 6 6 6 6
When the Scrub ON Button (G)
solution system flow starts when the Drive Paddle (3)
7 7 7 7 7
(3)
(3)
When the Drive Paddle (3)
(3)
(3) is in the neutral position, the brushes do not run and solution is not dispensed. Grip the Operator Control Handle
(15)
(15) and push the Drive Paddle (3)
(15)
(15)
(15)
best results, move the machine at a slow walking speed. Push the Solution Button (D)
Pull the Drive Paddle (3)
(3) backward to move the machine in reverse. The brushes will run while moving the machine in reverse, and solution
(3)
(3)
(3)
will be dispensed. NOTE:
NOTE: Raise the squeegee prior to moving the machine in reverse.
NOTE:
NOTE:
NOTE:
8 8 8 8 8
Begin scrubbing by moving the machine forward in a straight line at a normal walking speed and overlap each path by 2-3 inches (50-75
mm). Adjust when necessary the machine speed and solution flow according to the condition of the floor.
9 9 9 9 9
Adjust the Solution Flow Control Knob (10)
can be changed to allow variable solution flow for different types of floors to be scrubbed. Example: A rough or absorbent floor surface,
such as unfinished concrete, well require more solution than a smooth finished floor.
CAUTION !
CAUTION !
CAUTION !
CAUTION !
CAUTION !
To avoid damaging the floor, keep the machine moving while the brushes are turning.
10 10 10 10 10
When scrubbing, check behind the machine occasionally to see that all of the waste water is being picked up. If there is water trailing
the machine, you may be dispensing too much solution, the recovery tank may be full, or the squeegee tool may require adjustment.
11 11 11 11 11
For extremely dirty floors, a one-pass scrubbing operation may not be satisfactory and a "double-scrub" operation may be required. This
operation is the same as a one-pass scrubbing except on the first pass the squeegee is in the up position and the vacuum is turned OFF.
This allows the cleaning solution to remain on the floor to work longer. The final pass is made over the same area, with the squeegee
lowered to pick up the accumulated solution.
12 12 12 12 12
The recovery tank has an automatic float shut-off to prevent solution from entering the vacuum system when the recovery tank is full. When
the float shut-off is activated, the control system will shut down the scrub, vacuum and solution systems. The Scrub Pressure Hourmeter
Display (A)
(A)
(A)
(A)
(A) will display "FULL". To clear the display, press the Scrub OFF Button (H)
the float closes, the recovery tank must be emptied. The machine will not pick up water with the float closed. NOTE:
repeatedly gives a full indication when the tank is not full, the automatic shut-off feature can be disabled, have a qualified service technician
refer to the service manual to perform this function.
13 13 13 13 13
When the operator wants to stop scrubbing or the recovery tank is full, press and hold the Scrub OFF Button (H)
"0". This will automatically stop the scrub brushes and solution flow and the scrub deck will raise UP. NOTE:
be turned off when the button is only pressed once, this is to allow any remaining water to be picked up without turning the vacuum back
on. Press the Scrub OFF Button (H)
14 14 14 14 14
Move the machine to a designated waste water "DISPOSAL SITE" and empty the recovery tank. To empty, remove the Drain Hose (5)
it's hanger, then remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled flow of waste
water). Refill the solution tank and continue scrubbing.
NOTE:
NOTE:
NOTE:
NOTE: Make sure the Recovery Tank Cover (2)
NOTE:
44 44 44 44 44 - FORM NO. 56041519 - CMAX
(B)
(B)
(B) ON. This will display the control panel indicator lights, reference the Battery Condition Indicator (J)
(B)
(16)
(16)
(16)
(16) if installed.
(D)
(D) and hold for 5 seconds. This is done to pre-wet the floor. Note: This will help prevent scarring of the floor
(D)
(D)
(G)
(G)
(G)
(G) and lower the squeegee (17)
(17)
(17)
(17) to the floor. NOTE:
(17)
(G) is pressed, the brushes are automatically lowered to the floor. The machine's scrub brushes rotation and
(G)
(G)
(G)
(3)
(3)
(3)
(3) is activated.
(3)
(3) forward to start the brush motor, solution and vacuum systems and to move the machine forward. For
(3)
(3)
(10) so a thin, even layer of solution can be seen in front of the Squeegee (8). NOTE:
(10)
(10)
(10)
(H)
(H)
(H)
(H) a second time or press the Vacuum Button (E)
(2)
(2)
(2) and Recovery Drain Hose (5)
(2)
28ST, 34ST / I-MAX 28C, 32C / BA 750ST, 750C / BA 850ST
NOTE:
NOTE:
NOTE: Refer to the machine control description section for a
NOTE:
(D)
(D)
(D)
(D) to turn the solution OFF while making sharp turns.
(H)
(H)
(H), Scrub ON Button (G)
(H)
(E) and the vacuum will stop after a 10 second delay.
(E)
(E)
(E)
(5)
(5)
(5) are properly seated or the machine will not pick-up water correctly.
(5)
(J)
(J)
(J) and
(J)
(8). NOTE:
(8). NOTE:
(8). NOTE: The adjustment
(8). NOTE:
(G) or the Vacuum Button (E)
(G)
(G)
(G)
(E)
(E)
(E)
(E). When
NOTE:
NOTE:
NOTE:
NOTE: If the control
(H) until the display (A)
(H)
(H)
(H)
(A) reads
(A)
(A)
(A)
NOTE:
NOTE:
NOTE: the vacuum system will not
NOTE:
(5)
(5)
(5) from
(5)

Publicité

Table des Matières
loading

Table des Matières