Safety Information; Infrared Remote Control (Optional) - ExtraStove ES 9 Manuel D'installation

Masquer les pouces Voir aussi pour ES 9:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Dear Client,
We thank you for having chosen one of our products, the fruit of technological experience
and of continual research for a superior quality product in terms of safety, dependability,
and service.
In this manual you will find all the information and useful suggestions to use your product
with the maximum safety and efficiency.
Please remember that the first lighting of the stove must be handled
by our Authorized Assistance Centre (Law 37/2008) who will check
the installation and complete the guarantee.
• Incorrect installation, incorrectly performed maintenance, improper use of the product
release the manufacturer from every eventual damage derived from the use of the
stove.
• The unit cannot be used as an incinerator. Do not use fuels other than pellets.
• This manual has been realized by the manufacturer and constitutes an integral part
of the product and must remain with it during its entire lifetime. If the product is sold
or transferred, be sure that the booklet is present since the information contained in
it are addressed to the buyer, and to all those persons of various titles who complete
the installation, use and maintenance.
• Carefully read the instructions and the technical information contained in this manual,
before proceeding with the installation, use, and any operation on the product.
• The observance of the indications contained in the present manual guarantees the
safety of people and the product, the economy of use and a longer functioning life-
time.
• Although the carefully studied design and the risk analysis done by our company has
permitted the realization of a safe product, in any case, before effecting any operation
on the stove, it is recommended to keep said manual available and pay scrupulous
attention to the instructions written therein.
• Be very careful when moving the ceramic details where present.
• Check the precise flatness of the pavement where the product will be installed
• The wall where the product will be placed must not be constructed in wood, or in any
case, made of an inflammable material, and in addition it is necessary to maintain a
safety distance.
• While the stove is in operation, several parts of the stove (door, handle, sides) can
reach high temperatures. Therefore pay attention and use the proper precautions,
above all in the presence of children, elderly or disabled persons, and animals.
• Assembly must be performed by authorized persons (Authorized Assistance Centre).
• Diagrams and drawings are furnished for the purpose of illustration; the manufacturer,
with the intent of pursuing a policy of constant development and renewal of the product
can, without any notice, make any modifications that are believed opportune.
• When the stove is working at its maximum speed, it is strongly suggested to wear
gloves while handling with the door for pellets loading and the door handle.
• Installation is not recommended in a bedroom.
Never cover the body of the stove in any way or obstruct the ope-
nings placed on the upper side when the device is operating. All our
stoves are trial lighted on the construction line.
In the event of a fire, disconnect the power supply, use an extinguisher and call
the fire fighters if necessary. After that contact the Authorised Assistance Centre.
1.0 Norms and declarations of conformity
• Our company declares that the stove conforms to the following norms for EC European
Directive marking.
• 2004/108 EC (EMC directive) and successive amendments.
• 2006/95 EC (low voltage directive) and successive amendments.
• Regulation of the CPR (EU 305/2011).
• For installation in Italy refer to the UNI 10683/98 or successive modifications; the te-
chnician installing the hydrothermal sanitary system will issue the declaration of con-
formity according to L. 37/2008. The installation of appliance has to be in accordance
with local and national laws and with European norms.
• EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 60335-1;
EN 60335-2-102; EN 62233; EN 14785.

1.1 Safety Information

Please carefully read this use and maintenance manual before installing and operating
the stove!
If clarification is needed, please contact the dealer or the Authorized Assistance Centre.
• The pellet stove must only be operated in living environments. This stove, being con-
trolled by an electronic board, permits a completely automatic and controlled combu-
stion; the exchange, in fact, regulates the lighting phase, 5 power levels and the shut
down stage, guaranteeing the safe operation of the stove.
• The basket used for combustion allows most of the ash produced by the combustion
of the pellets to fall into the collection compartment. Nevertheless, check the basket
daily, given that not all pellets have high quality standards (use only quality pellets re-
Instructions
commended by the manufacturer).
• The glass is equipped with a special circulation of air for self-cleaning, but still, it is
not possible, after several hours of operation, to keep a light grey patina from forming
on the glass. This also depends on the type of pellets used. Some pellets deposit more
ash than others.
1.2 Responsibility
With the delivery of the present manual, we decline all responsibility, both civil and penal,
for accidents deriving from the partial or total lack of observance of the instructions
contained herein.
We decline every responsibility derived from improper use of the stove, from incorrect
use by the user, from unauthorized modifications and/or repairs, from the use of re-
placement parts that are not original for this model.
The manufacturer declines every civil or penal, direct or indirect responsibility due to:
• Lack of maintenance;
• Failure to observe the instructions contained in the manual;
• Use in non-conformity with the safety directives;
• Installation in non-conformity with the norms in force in the country;
• Installation by unqualified or untrained personnel;
• Modifications and repairs not authorized by the manufacturer;
• Use of non-original replacement parts;
• Exceptional events.
• The stove must only be fed with quality 6mm diameter pellets of
the type recommended by the manufacturer;
• Before making the electrical connection of the stove the discharge
tubes must be connected with the flue;
• The protective grill placed inside the pellet container must never
be removed;
• The environment where the stove is installed must have a suffi-
cient exchange of air;
• Never open the door of the stove while it is operating;
• When the stove is operating, the surfaces, glass, handle and tubes
become very hot: during operation do not touch these parts wi-
thout adequate protection;
• Keep/store the pellets in a cool dry place;
• Keep the fuel and other inflammable materials off the stove.
2.0 The Stove Panel
1
2
3
1) Key "SET": Used to enter the menu and confirm data changes during setting.
2) Key "AUTO": Allows you to change from Automatic to Manual, the operation mode of
the stove.
3) Key "ON / OFF": Turn on and off of the stove. If an error occurs, press for a few se-
conds, this will reset the alarm. Also used to exit the menu without changing the data.
4) Key "TEMP+": to increase the desired temperature. Also used to scroll through menus
and data.
5) Key "TEMP-": to decrease the desired temperature. Also used to scroll through menus
and data.
6) Key "PROG +": to increase the program or power functioning desired. Also used to
scroll through menus and data.
7) Key "PROG-": to decrease the program or power functioning desired. Also used to
scroll through menus and data.

2.1 Infrared Remote Control (Optional)

The system foresees the use of the optional IR remote control, which can be installed at
any time. The remote control allows the switching on and off of the stove, at a distance.
Before use, it becomes necessary to store the code of the remote control. This is done
directly from the panel of the stove without using any tools.
2.1.1 Storing code
Press for about 5 seconds Press "PROG+" and "TEMP+", until the display reads "IR RE-
MOTE". Then direct the remote control toward the panel and press any of the buttons.
A beep will alert you perform a successful operation.
Exit the menu by pressing "STOP" and try to control the stove.
17
G
4
6
5
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Es 10Es 12Es 16Es 16cEs plus 10Es plus 12

Table des Matières