Safety Notes

en
Working safely with the measuring
tool is possible only when the
operating and safety information
are read completely and the in-
structions contained therein are
strictly followed. Never make warning labels
on the measuring tool unrecognisable.
SAVE THESE INSTRUCTIONS.
Caution – The use of other operating or
adjusting equipment or the application of
other processing methods than those men-
tioned here, can lead to dangerous radia-
tion exposure.
The measuring tool is provided with a warn-
ing label in English (marked with number 13
in the representation of the measuring tool
on the graphics page).
Do not direct the laser beam at persons
or animals and do not stare into the laser
beam yourself. This measuring tool produces
laser class 2 laser radiation according to
IEC 60825-1. This can lead to persons being
blinded.
Do not use the laser viewing glasses as safety
goggles. The laser viewing glasses are used for
improved visualisation of the laser beam, but
they do not protect against laser radiation.
Do not use the laser viewing glasses as sun
glasses or in traffic. The laser viewing glass-
es do not afford complete UV protection and
reduce colour perception.
Have the measuring tool repaired only
through qualified specialists using original
spare parts. This ensures that the safety of
the measuring tool is maintained.
Bosch Power Tools
Do not allow children to use the laser meas-
uring tool without supervision. They could
unintentionally blind other persons or them-
selves.
Do not operate the measuring tool in explo-
sive environments, such as in the presence
of flammable liquids, gases or dusts. Sparks
can be created in the measuring tool which
may ignite the dust or fumes.
Keep the measuring tool and the
laser target plate 15 away from
cardiac pacemakers. The magnets
of the measuring tool and laser tar-
get plate generate a field that can
impair the function of cardiac
pacemakers.
Keep the measuring tool and the laser tar-
get plate 15 away from magnetic data medi-
um and magnetically-sensitive equipment.
The effect of the magnets of the measuring
tool and laser target plate can lead to irre-
versible data loss.

Functional Description

Please unfold the fold-out page with the repre-
sentation of the measuring tool and leave it un-
folded while reading the operating instructions.

Intended Use

The measuring tool is intended for determining
and checking horizontal and vertical lines.