uSER INTRucTIoNS
1.
Remove the mask and the headgear from the package.
2.
Place the headgear on a table, label side down with the narrowest part close to you.
3.
Set the mask with the gel side down onto the center of the headgear.
4.
Take each headgear strap and connect it to its respective location on the mask by looping the Velcro strap through
the headgear slots and attaching it back to itself (Figure 2).
5.
Once the headgear has been properly attached to the mask, follow the fitting tips below to fit the mask:
6.
Detach one Velcro strap by sliding the Velcro loop off the quick release hook, slip the headgear over the head and
center the mask on the face.
7.
Find the detached Velcro strap and slide the Velcro loop back on the quick release hook (Figure 3).
8.
Be sure the headgear straps are parallel and the headgear is fully extended and flat around the crown of the head
(Figure 4).
9.
Adjust the bottom headgear straps by using the Velcro tabs. Make sure the Active Headgear Connector is parallel to
the face and that there is equal tension from the headgear on both sides. After tightening, make sure the Active
Headgear Connector can move freely (Figure 5).
NOTE: Do NOT over tighten the headgear.
10. Adjust the upper headgear straps by using the tabs (Figure 6).
11. Adjust the bottom headgear straps to make sure the bottom of the mask is seated comfortably on the face.
NOTE: For optimal seal and comfort, mask should be snug but not tight. Adjust the tension by detaching the Velcro straps,
tightening or loosening the straps, and reattaching the Velcro .
12. Connect the mask tubing assembly to the positive airway pressure device tubing and turn the device on to the
prescribed pressure (Figure 7).
13. Turn head from side to side while lying on the bed and identify areas of leak that may prevent sleep.
14. In the event of leaks, tighten the Velcro tabs closest to the area of leak. Do NOT over tighten the headgear.
15. If leaks persist, try moving the mask higher or lower around the nose to find the best fit.

gENERal INFoRMaTIoN

CONTENTS: Innova Full Face Vented Mask with Headgear
This product is not manufactured with natural rubber latex
Rx ONLY
MADE IN U.S.A. of US and Imported Parts
The mask has a non-transferable three month limited warranty for manufacturer's defects from the date of purchase by the
initial consumer. If a mask used under normal conditions should fail, DeVilbiss will replace the mask or its components. For
additional information about the DeVilbiss Warranty, please visit http://www.devilbisshealthcare.com.
NOTE: Please dispose of the mask and accessories in accordance with local and regional guidelines.
NOTE: THIS PRODUCT IS NOT MANUFACTURED WITH NATURAL RUBBER LATEX.

clEaNINg aND MaINTENaNcE - SINglE paTIENT uSE

Cleaning is recommended on a daily basis.
detergent. Rinse thoroughly after washing. Visually verify that the vent holes are clear, and allow the mask to air dry.
Washing your face prior to fitting the mask will remove excess facial oils and help extend the life of the mask.
NOTE: Inspect mask prior to each use. Replace the mask if parts are damaged or gel is exposed due to tear or
punctures.
NOTE: The gel cushion, although silky to touch, will not tear, leak or detach from the mask under normal use and
following recommended cleaning and maintenance protocols. However, the gel cushion is not indestructible. It will tear, cut
and rip if subjected to mishandling or abuse. The warranty does not cover these types of product failures. Therefore,
please handle your new mask with care.
Weekly Cleaning (if desired): The Innova Mask is dishwasher safe if placed in top rack; small components should be
secured. Air dry before use.
90150
Hand wash the mask and headgear (as needed) in warm water using a mild
EN-5