MOTOR AND RACK FITTING
The rack shall be fitted over the motor support, at a certain distance from It.
Its height can be adjusted thanks to the holes In the rack.
The height adjusting is necessary to prevent the gate leaning on the driving gear (5 and 6).
To fix the rack on the gate, drill some Ø 5 mm holes and thread them using an M6 screw tap.
The driving gear needs some 1 mm clearance from the rack.
Measurements in mm/inch
LIMIT SWITCH ADJUSTMENT SUPER 2200 FCE
To adjust the assembly: release nuts G, after establishing the direction of movement of cam
H for opening and closing, position the two limit switches, F, by turning knobs P and judging
by sight.
After checking for correct operation of the two microswitches, precisely adjust their positions
so that the gate will stop in the desired position during opening and closing. Then fasten nuts
G.
N.B. The standard limit switch is used for gates up to 10,5 meters long.
LIMIT SWITCH FITTING SUPER 2200 FCM
In order to determine the gate travel length, place two cams at the ends of the rack (8).
Move the cams on the rack teeth to adjust their opening and closing travel.
To fix the cams to the rack, tighten the screws issued.
N.B: In addition to the electric stop cams mentioned above, you must also install strong
mechanical stops preventing the gate from sliding out from the top guides.
MAINTENANCE
To be carried out exclusively by skilled persons after the power supply to the motor has
been interrupted.
Periodically, when the gate is standstill, clean and keep the guide free from stones and dirt.