Aircare D46720 Manuel D'utilisation Et D'entretien page 9

Masquer les pouces Voir aussi pour D46720:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
Trouble
Digital display not
illuminated.
Fan not operating
(digital display is
illuminated).
Fan running
continuously.
Poor evaporation of
water.
Neither bottle
emptying.
Left bottle not
emptying.
Water leaking from
unit
Control panel does
not respond to input.
Display shows CL
Display flashes "20"
Display flashes "—"
Probable Cause
• No Power.
• Power button has not
been depressed.
• Room 3% or more below
SET humidity level.
• Bottles are empty.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
• CHECK FILTER (CF)
message flashing.
• Mineral buildup on filter
(wick).
• Unit is not level
• Bottle valve stem is not
positioned correctly
• Dirty wicks.
• Right bottle contains
water.
• Bottle caps not properly
tightened or situated
• Control lock feature has
been turned on to
prevent changes in
settings.
• Room Humidity is
lower than 20%.
• Unit initiating.
• Room humidity is over
90%.
• Check 120 volt power source.
• Press power button once to
turn on.
• Raise SET humidity level if
desired.
• Increase fan speed.
• Fill humidifier with water.
• A SET humidity percentage of
65% operates fan continuously.
Adjust SET level between 25%
- 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to new wick
NOTE: Local water varies from
area to area and under certain
conditions minerals will build up
more rapidly in the wick.
• Unplug unit for 1-2 minutes to
reset CF function
• Ensure unit is placed on level
area
• Check orientation of bottles.
Reposition so that bottle
valve stem is depressed by
post in bottom of cabinet.
• Change to fresh wicks
•The humidifier is designed so
that right bottle empties first.
• Ensure unit is level
• Check that valve stem is secure
and bottle cap is tight and
correctly aligned in base.
• Press Humidity and Speed
buttons at same time for 5
seconds to deactivate feature.
• Will read actual humidity when
level comes up to 25%.
• Room humidity will display after
initiation is complete.
• Will remain until humidity drops
below 90%.
9
Remedy

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D46720 cn

Table des Matières