3) Remove the bottle fill cap and fill bottle by placing the opening under the faucet. Fill
with cool tap water or bottled distilled water. If you only have softened water available,
you may use it, but you will notice mineral buildup on the wick much sooner.
4) Upon first fill-up, it will take approximately 30 minutes for the wicks to absorb
the water from the base of the unit. After initial saturation, the tank should be
refilled again for maximum running time. Refill the bottle when the refill
indication illuminates.
CAUTION: Do not spill water on fan motor. Electrical components must be kept
dry.
NOTE: We recommend using AIRCARE
when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat
according to the instructions on the bottle.
Under no circumstances should you use Water Treatment products intended for
Rotobelt or Ultrasonic humidifiers.
IMPORTANT: Water damage
may result if condensation
starts to form on windows or
walls. Humidity SET point
should be lowered until
condensation no longer forms.
We recommend room humidity
levels do not exceed 50%.
NOTE: External hygrometer readings and humidistat readings may differ. Humidity
levels can vary significantly even in one room. The amount of time it takes to affect
the room humidity depends on the relative humidity of the air. In especially dry areas
it could take up to 48 hours to see humidity climb to the desired level.
*A digital hygrometer is available for purchase by calling 1-800-547-3888.
OPERATION
Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier
should be placed at least FOUR inches away from any walls and away from heat
registers. Unrestricted airflow into the unit will result in the best efficiency and
performance.
NOTE: This unit has an automatic humidistat located on the cord that senses the
humidity level around the immediate area of the humidifier. It turns the humidifier on
when the relative humidity in your home is below the humidistat setting and will turn
the humidifier off when the relative humidity reaches the humidistat setting.
®
®
or Essick Air
Bacteriostat Treatment
When Outdoor
Temperature is:
°F
° C
-20
-30°
-10°
-24°
-18°
10°
-12°
20°
-6°
30°
-1°
5
Recommended
Indoor Relative
Humidity (RH) is
15 - 20%
20 - 25%
25 - 30%
30 - 35%
35 - 40%
40 - 45%