Adapters For Danfoss - eQ-3 eqiva L Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.2

Adapters for Danfoss

One of the provided adapters is required to attach to Danfoss
valves. The arrangement of the suitable adapter ring for the ap-
propriate valve can be found in the following figures:
Take care during installation that you do not trap your
fingers between the two halves of the adapter!
The Danfoss valve bodies have elongated indentations (E) run-
ning all around (see arrow), which also ensure better seating of
the adapter after it has been latched into place.
During installation, please ensure that the pins inside the
adapter (D) are lined up with the notches (E) on the valve.
Ensure that a suitable adapter for the valve is properly
clipped on.
The RA and RAV adapters have been manufactured with pre-
tension in order to provide a better seat. Use a screwdriver
during installation if necessary, and bend it open slightly in the
vicinity of the screw. After clipping onto the valve body, please
attach the adapter using the provided screw and nut.
38 38

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières