Operation; Activate Heating Pause (Battery Saving); Frost Protection Mode; Boost Function - eQ-3 eqiva L Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11 Operation

11.1 Activate heating pause (battery saving)

Battery life can be prolonged by switching the heating off in
summer. To achieve this, the valve is opened fully. The calcifica-
tion protection continues to run.
To activate the heating pause, proceed as follows:
• Turn the control wheel in manu mode (manu) to the right un-
til "On" appears in the display.
• To end it, exit the manu mode (manu) or turn the selector
dial to the left.

11.2 Frost protection mode

If a room is not to be heated, the valve can be closed.
• Turn the control wheel in manu mode (manu) to the left until
"OFF" appears in the display.
The valve is only opened if there is a risk of frost. The calcifica-
tion protection continues to run.
• To end it, exit the manu mode (manu) or turn the control
wheel to the right.

11.3 Boost function

The boost function makes use of human sensations of heat.
When activated, the heating valve is immediately opened to
80 % for 5 minutes (factory setting). The heating of a room
takes longer than 5 minutes, but the heat given off by the radi-
ator can be felt immediately. If, for example, you arrive home