Festo DGC-8/12 Notice D'utilisation page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
DGC-8/12
Fitting the pneumatic components
Setting the slide speed
Screw a one-way flow control valve of type GRLA-... into the compressed air
S
ports.
Fitting in a vertical or diagonal position
Warning
If there is a drop in pressure, the work mass will slide down. Moving masses can
cause injury to people or damage to property (danger of fingers being
squashed).
S Check whether non-return valves of type HGL-... are required here.
In this way you can prevent the work mass from sliding down.
Definition: work mass = mass of work load + slide mass
Select the compressed air ports.
S
In addition to the compressed air
ports (A) provided at the factory,
there are also the alternative ports
(B, C). These are fitted with blanking
plugs.
L slide position left
R slide position right
Fitting the electric components
If you are using proximity switches to scan positions:
Avoid fastening the cylinder directly onto ferritic parts.
S
Make sure that the minimum distance be-
S
tween static or moving ferritic masses and
the proximity switches type SME/SMT-10-...
corresponds to the values specified in Fig. 17.
In this way you will avoid incorrect switching
as a result of external influences.
DGC-8-...
DGC-12-...
Fig. 17
22
C
Fig. 16
L1: 0 mm
L2: 20 mm
L1: 0 mm
L2: 10 mm
C
B
A
L
Festo DGC-8/12 0212NH English
B
A
R

Publicité

Table des Matières
loading

Table des Matières