3/ The green "mains" LED shows the status of the power
supply for the remote alarm module:
- On steadily = module powered by the mains supply
- Flashing = mains supply fault for the module (which is
thus operating on its battery power supply)
- Off = module failure or module battery flat
4/ The buzzer stays on continuously during an alarm.
It stops if the alarms are no longer present or if you press
the button «Reset» General Alarm.
10
CONFORMITY WITH STANDARDS
®
• SANICUBIC
2 Pro complies with standard EN 12050-1 (lift
station for household waste containing faeces) and with the
European directives covering construction products, electri-
cal safety and electromagnetic compatibility
This unit must be installed and used in compliance with
European installation standard EN12056 and with local
requirements.
11
COMMISSIONING
1- Once the plumbing and electrical connections have
been made, check that the connections are watertight
by letting water flow successively through each inlet
used. Make sure that the unit is operating correctly by
carrying out at least two start cycles with water to test
the system.
2 -
WARNING!
Do not operate the motors in override
status (by pressing the pushbuttons on the control
box) until the pumps have been filled with water.
Operation without water damages the maceration
system.
12
USE
®
1- The SANICUBIC
2 Pro unit is designed to drain off
household waste water. Any other use will invalidate the
guarantee. Do not dispose of sanitary towels, condoms,
hygiene articles, oils, solvents, acids, or any other poten-
tially corrosive or explosive liquids etc., via the unit.
2-
WARNING: In the event of a power failure, stop
draining any water from the equipment connected
to the SANICUBIC
®
3- Do not install or use the unit in a zone where there is a
risk of explosion.
13
MAINTENANCE
A visual check of the lift station must be made once a month
to make sure it is operating correctly, and the installation
must be inspected regularly (once a year) by a qualified per-
son. Meanwhile if encounter technical problems, please ask
our after-sales service for advice. If the power supply cable
of the unit is damaged, it must be replaced by the manufac-
turer or its after-sales service to avoid all danger.
14
GUARANTEE
The SANICUBIC
®
2 Pro unit is guaranteed for two years
(parts and labour) provided that it has been installed and
used in compliance with the present instructions.
2 Pro unit.