SFA Sanicubic 2 Pro Notice D'installation page 7

Masquer les pouces Voir aussi pour Sanicubic 2 Pro:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
UK
The numbers refer to the explanatory diagrams.
Fully illustrated step by step
instructions are downloadable
on www.saniflo.co.uk
1
DESCRIPTION
®
The SANICUBIC
2 Pro is a lifting station
designed to evacuate effluent from small
private or commercial units.
Please comply with all the installation
and maintenance specifications set out
in these instructions, and especially the
information marked with the following
signs:
«
» Failure to comply with this
information could entail safety
hazards for personnel,
«
» Information warning of the pre-
sence of an electrical hazard,
«
» Instructions only for qualified
professional specialists,
«WARNING» Failure to comply with this
information could affect the normal
operation of the equipment.
Please contact our Customer service for
further information.
SANICUBIC OPERATING PRINCIPLE
®
SANICUBIC
2 Pro contains 2 separate
pumps. Each of the pumps is fitted with a
high-performance maceration system.
The 2 pumps operate alternately. In the
event of inflow overload, both motors run
at the same time (or if one of the pumps
is faulty, the other one takes over).
®
The SANICUBIC
2 Pro tank is fitted with
2 dip tubes; one tube controls motor
operation, and the other one controls the
alarm system.
- Long pickup tube (normal operation): as
soon as the waste water level in the tank
reaches the triggering point in the long
tube, the pumping system starts up.
- Short pickup tube (inflow overload
operation): if the waste water level in the
tank reaches the upper point, a contact
is closed, and the auxiliary pumping
system is triggered. The contact also
sets off an audible and visual alarm. The
general alarm LED on the SANICUBIC
2 Pro control panel switches to red. The
system sends a high-frequency malfunc-
tion signal to the remote alarm unit. The
®
SANICUBIC
2 Pro is fitted with a remote
alarm module that transmits a visible and
audible alarm (HF link).
2
LIST OF PARTS SUPPLIED
3
DIMENSIONS
4
TECHNICAL DATA SANICUBIC
Type
Maximum discharge head
Voltage
Frequency
Volume
Maximum power input
Maximum current input
Electrical classification
Ave water temp for optimum performance 35°C
Maximum temperature (intermittent)
Protection index
Net weight (including accessories)
*Hot water drain cycles from dishwashers or washing machines
5
FIELD OF APPLICATION
Household waste water (the combined
inputs must not exceed 80% of those
shown in the graph
6
PERFORMANCE CURVE
Example: Pump P1 is operating nor-
mally. It discharges 160 l/min at a pum-
ping height of 5 m. If pump P1 shows any
signs of weakness or if the waste water
inflow is too great, pump P2 starts up.
The output is then increased to about 275
l/min, until the situation returns to normal.
7
RATIO OF HEIGHT/LENGTH
FOR DISCHARGE
8
INSTALLATION
The SANICUBIC
in compliance with standard EN12056.
The equipment must be commissioned
and maintained by a qualified professio-
nal specialist.
Please refer to installation standard
EN 12056.
REGULATIONS
8a
1- Attention: the space in which the
SANICUBIC
must be large enough to leave at least
600 mm of working room around and
above the unit to facilitate such
maintenance work as may be required.
There must be sufficient lighting, and it
must be sufficiently well ventilated and
protected from freezing.
®
2- Isolating valves (not supplied) must
be fitted on waste inlets (especially
the 110mm inlets) and on the dis-
charge to ensure that any
service/maintenance may be carried
out safely).
3- The discharge pipe must be fitted
so as to avoid all back flow from the
drainage system (see the examples in
drawing
). Back flow can be avoided
8g
by installing an anti-back flow riser
reaching a high point above the
maximum back flow level.
®
2 Pro
Comment: In the absence of local
R300
information to the contrary, the
11 m
maximum back flow level corresponds
220-240V
to street level (roadway, pavements,
etc.). Continue the discharge pipework
50 Hz
after the anti-backflow riser, using a
47 l
larger diameter pipe.
3000 w
4- If the SANICUBIC is installed in a
13 A
space such as a pit for example, we
I
would recommend the fitting of a bilge
pump in case of flooding.
70°C*
5- The lifting station must be vented with
IP67
an outlet at roof level.
30 kg
6- The lifting station must be fixed to the
floor (see paragraph
).
6
®
2 Pro must be installed
®
2 Pro is to be installed
).
8h
CONNECTING THE DISCHARGE
8b
PIPE
Remove the end cover or covers from the
back of the unit (cf.
).
8g
1
As each pump is fitted with a macerator
system, an ND50 mm discharge pipe can
be used.
The discharge bend is at the centre of the
unit, at the back (cf.
). Use the sleeve
8b
to connect it to the riser pipe and fix it
D
in place with the collars.
Each pump in the SANICUBIC
unit is fitted with check valves.
See paragraph
regarding control
8a
valves and back flow.
CONNECTING SANITARY
8c
EQUIPMENT TO THE LOWER
INLETS
If you want to install a shower or a
bath at the same level as the
SANICUBIC
2 Pro, you must
®
make sure that the upper parts of the
plugholes on the sanitary equipment are
at least 250 mm above the lower inlets.
CONNECTING THE INLETS ND
8d
40/50
Lower inlets (cf.
)
8d
1
Upper inlets (cf.
)
8d
2
• Cut off the end of the ND 50 inlet with
a saw
• Cut the sleeve
to suit the pipe
D
diameter: ND 40 or ND 50 (cf.
• Fix the sleeve
on the inlet and on the
D
pipe, using the collars.
CONNECTING THE ND 100/110
8e
INLET
Lower inlets (cf.
)
8e
1
1- Remove the plug from the side inlet.
2- Fix the sleeve
in place using the
F
collar
.
J
3- Fully insert the ND 100/110 tube in
the other end of the sleeve and fix it in
place using the other collar
Upper inlets (cf.
)
8e
2
1- Cut off the upper end of the ND 100
inlet with a saw.
2- Fix the sleeve
in place using the
F
collar
.
J
3- Fully insert the ND 100/110 tube in
the other end of the sleeve and fix it in
place using the other collar
CONNECTING THE VENT
8f
The SANICUBIC
®
2 Pro must be vented
with an outlet at roof level.
Fix the sleeve
in place using the
D
collar
.
C
Fully insert the ND 50 tube in the other
end of the sleeve and fix it in place using
the other collar
.
C
WARNING: Do NOT fit air admittance
valve on the top of the air vent pipe. The
vent must be an open vent or the unit will
not operate.
®
2 Pro
)
8d
3
.
J
.
J

Publicité

Table des Matières
loading

Table des Matières