Automation system ---> TMT184 (display value)
Process
Output Byte
parameter
0, 1, 2, 3
Display value
4
Status display value
Generally the projecting of a PROFIBUS-DP/-PA
1.
The unit to be set up (TMT184) is connected to the PROFIBUS-PA
files in the configuration programme of the automation system. The values that are required
can be set up offline in the projecting software.
2.
The operator programme of the automation system should now be set up. The in and output
data is controlled and fixed using the operator programme. Here the measured values can be
found in order to be able to analyse them. If the automation system does not support the IEEE-
754 floating decimal point format then an addition measured value conversion block must be
used. Dependent on the type of data management used by the automation system (Little-
Endian-Format or Big-Endian-Format), a change in the byte sequence may be needed (byte-
swapping).
3.
Once the projecting has been completed this is transmitted to the automation system as a
binary file.
4.
The system can be started once the projecting sequence has been completed. The automation
system connects to the projected units. Now the process relevant unit parameters can be set
up using a class 2 master, e.g. using Commuwin II.
Status code
Status codes, supported by the AI block (analogue input).
Coding for the status in compliance with the PROFIBUS Profiles 3.0 'PROFIBUS-PA Profile for Pro-
cess Control Devices - General Requirements' V 3.0:
Status Code
0x1C
OUT_OF SERVICE
0x1D
OUT_OF SERVICE
0x1E
OUT_OF SERVICE
0x1F
OUT_OF SERVICE
0x0C
DEVICE_FAILURE
0x0D
DEVICE_FAILURE
0x0E
DEVICE_FAILURE
0x0F
DEVICE_FAILURE
0x44
LAST_USABLE_VALUE
0x45
LAST_USABLE_VALUE
0x46
LAST_USABLE_VALUE
0x47
LAST_USABLE_VALUE
0x48
0x49
0x4A
0x4B
0x4C
0x4D
0x4E
0x4F
Access
Comments/Data format
mode
Write
32 Bit floating decimal point number (IEEE-754)
Write
-
®
system is as follows:
Meaning
SUBSTITUTE_SET
SUBSTITUTE_SET
SUBSTITUTE_SET
SUBSTITUTE_SET
INITIAL_VALUE
INITIAL_VALUE
INITIAL_VALUE
INITIAL_VALUE
®
network using the GSD
Unit condition
BAD
BAD
LOW_LIM
BAD
BAD
BAD
BAD
LOW_LIM
BAD
BAD
UNCERTAIN
UNCERTAIN
LOW_LIM
UNCERTAIN
UNCERTAIN
UNCERTAIN
UNCERTAIN
LOW_LIM
UNCERTAIN
UNCERTAIN
UNCERTAIN
UNCERTAIN
LOW_LIM
UNCERTAIN
UNCERTAIN
5 Operation
Limits
OK
HIG_LIM
CONST
OK
HIG_LIM
CONST
OK
HIG_LIM
CONST
OK
HIG_LIM
CONST
OK
HIG_LIM
CONST