Enerzone Solution 3.5 Manuel D'installation Et D'utilisation page 166

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 9/6/2018 2:01:07 PM
Test report 103536746MTL-002 (19 of 21)
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103536746MTL-002
Date: 07/13/18
TABLE 6 - CSA B415.1 RESULTS
BURN RATE
(kg/hr)(dry)
Low – 1.3
Medium – 1.7
High – 3.9
TABLE 7 – WEIGHTED AVERAGE CALCULATION
Test
Burn
No.
Rate
2
1.3
3
1.7
4
3.9*
SECTION 11
CONCLUSION
This test demonstrates that this unit is an affected facility under the definition given in the
regulation. The emission rate of 1.37 g/hr meets the EPA requirements for the Step 2 limits.
Version: 05/10/17
Stove Builder International Inc. | 44826 | Rev: Aug 31 2018 3:17PM | Uncontrolled Copy
CO
EMISSIONS
EFFICIENCY (% HHV)
(g/min)
1.3
1.7
1.6
(E)
(CO)
Heat
HHV
Average
Avera
Output
Emission
ge
(Btu/hr)
Rate g/hr
Emissi
on
Rate
g/hr
0.74
81
18,200
72
1.48
97
22,700
71
2.18
33
51,100
69
TOTALS:
HEATING
Heating
Efficiency
(% LHV)
72%
78%
71%
76%
68%
73%
LHV
(K)
(KxE)
(KxC
Weightin
g/hr
O)
g Factor
g/hr
77
40%
0.30
32
76
40%
0.59
39
75
20%
0.44
7
100%
1.32
78
Page 19 of 21
8431 Murphy Drive
Middleton, WI 53562
Telephone: 608-836-4400
Facsimile: 608-831-9279
www.intertek.com/building
HEAT OUTPUT
(Btu/hr)
18,100
22,700
49,500
(KxC
(KxH
(KxLH
O)
HV)
V)
g/min
0.84
29
31
0.37
28
30
0.16
14
15
1.37
71
77
GFT-OP-10c
Page 174 of 201

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Eb00053

Table des Matières