Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 9/6/2018 2:01:07 PM
TESTING INFORMATION
Test Report 103328128MTL-001
The SBI Model 3.5 Series Wood Fuel Room Heater has been found to be in compliance with the applicable
performance requirements of the following criteria: "CSA B415.1-2010(R2015) – Performance Testing of Solid-
Fuel-Burning Heating Appliances", ASTM E2515-2011-Standard test method for determination of particulate
matter emissions collected by a dilution tunnel, ASTM E3053-2017- Standard test method for determining
particulate matter emissions from wood heaters using cord wood test fuel.
Testing was performed at the client's facility located in St-Augustin, Quebec. QC.
To make this SpecDIRECT document less voluminous, a number of appendices to the attached report were
omitted. They can be found in EPF under the identified project number as well as in documentation supplied to
EPA..
Stove Builder International Inc. | 44826 | Rev: Aug 31 2018 3:17PM | Uncontrolled Copy